Operation / Service
5. DO NOT remove grounding prong from plug or mod-
ify plug.To protect against electrical shock, the power
cord is a three-wire conductor and includes a
3-prong grounded plug. Plug pump into a 3-wire,
grounded, grounding-type receptacle. Connect pump
according to electrical codes that apply.
For automatic operation, plug or wire pump into an auto-
matic float switch or pump controller. Pump will run con-
tinuously when plugged directly into an electrical outlet.
Connect or wire pump to its own individual branch circuit
with no other outlets or equipment in the circuit. Size
fuses or circuit breakers according to chart on Page 2.
Risk of electrical shock and fire. Can burn or
cause death. Be sure that power supply information
(Voltage/Hertz/Phase) on pump motor nameplate matches
incoming power supply exactly. Install pump according to
all electrical codes that apply.
OPERATION
NOTICE: Do not allow pump to run in a dry sump. It
will void the warranty and may damage the pump.
An automatic overload protector in the motor will pro-
tect motor from burning out due to overheating/overload-
ing. When motor cools down, overload protector will
automatically reset and start motor.
If overload trips frequently, check for cause. It could be a
stuck impeller, wrong/low voltage, or electrical failure in
motor. If an electrical failure in the motor is suspected,
have it serviced by a competent repairman.
Pump is permanently lubricated. No oiling or greasing is
required.
WARNING
Risk of electrical
shock.
Can burn or kill.
Do not lift pump by
power cord.
For parts or assistance, call Flotec Customer Service at
SERVICE
cause death. Before removing pump from basin for ser-
vice, always disconnect electrical power to pump and
control switch.
Do not lift pump by power cord. See "Cord Lift Warning"
below.
Submerge pump in a disinfectant solution (chlorox or
chlorine) for at least one hour before servicing pump.
The pump motor contains a special lubricating oil which
should be kept clean and free of water at all times.
Check operation by filling sump with water and observ-
ing pump operation through one complete cycle.
or property damage. Failure to make this operational
check may lead to flooding and premature failure.
NOTICE: This unit is not designed for applications
involving salt water or brine! Use with salt water or brine
will void warranty.
REPAIR PARTS
Power Cord: 10', 115 V ..................................21628B046
Tethered Float Switch..............................PW117-267-TSE
Impeller..........................................................26053B000
electrical power before replacing cord or switch. Do not
remove impeller housing (volute). There are no consumer
serviceable parts inside the pump.
CORD LIFT WARNING
Hazardous voltage. Can shock, burn, or
Risk of electrical shock. Can burn or kill.
Risk of flooding. May cause personal injury
Hazardous voltage. Disconnect pump from
1. Attempting to lift or support pump by
power cord can damage cord and
cord connections.
2. Cord may pull apart, exposing bare
wires with possibility of fire or electri-
cal shock.
3. Lifting or supporting pump by power
cord will void warranty.
4. Use lifting ring or handle on top of
pump for all lifting/lowering of pump.
Disconnect power to pump before
doing any work on pump or attempt-
ing to remove pump from sump.
1-800-365-6832