Troubleshooting Guide - EINHELL GC-DW 900 N Manual De Instrucciones

Bomba sumergible a presión
Ocultar thumbs Ver también para GC-DW 900 N:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
Anleitung_GC_DW_900_N_SPK7__ 25.06.13 10:26 Seite 11

10. Troubleshooting guide

Faults
The equipment does not start
The equipment does not pump
The equipment does not cut out
Insufficient pumping rate
The equipment switches off after
briefly running
Cause
Power supply not connected
-
Floating switch does trigger
-
-
Intake sieve clogged
-
Discharge hose kinked
Floating switch cannot sink
-
Intake sieve clogged
-
Performance reduced due to
-
heavily contaminated and
abrasive water impurities
Motor circuit-breaker switches
-
the equipment off due to
excessive water contamination
-
Water temperature too high;
motor circuit-breaker switches
the equipment off
GB
Remedy
Check power supply
-
Raise position of floating switch
-
-
Clean intake sieve with water jet
-
Unkink the hose
- Lower the position of the floating
switch.
Clean intake sieve
-
Clean equipment and replace
-
wear parts
Unplug power plug and clean
-
equipment and shaft
-
Ensure that maximum
permissible water temperature
(35 °C) is not exceeded
11

Publicidad

Tabla de contenido
loading

Tabla de contenido