Reassembling The Unit - Oase Filtral UVC 700 Instrucciones De Uso

Ocultar thumbs Ver también para Filtral UVC 700:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

- English -

Reassembling the unit

Filtral 700
 S, T, U, V
Bolt the pump (28) to the UVC water housing (26) using the union nut. Insert fine foam filter (22) in the bottom strainer
casing (2), place the bio surface elements (23) and the gravel bag (24) in the bottom strainer casing (2). Insert the UVC
clarifying unit including the pump (20). Insert the foam filter (3). Attach the top strainer casing (1) and press it onto the
bottom strainer casing (2) until the clamps engage in the bottom strainer casing. Important: Guide the connection ca-
ble (7) through the cable opening at the bottom strainer casing (2) and clip with the cable kink protection in the bottom
strainer casing (U, 37).
Filtral 1200
Bolt the pump (28) to the UVC water housing (26) using the union nut. Place the bio surface element (23) and gravel
bags (24) in the bottom strainer casing (2). Place the aeration stone (25) between the gravel bags (24). Ensure that the
hose is not kinked. Place the foam filters (3, 22) in the bottom strainer casing (2). Insert the UVC clarifying unit in-
cluding the pump (20). Attach the top strainer casing (1) and press it onto the bottom strainer casing (2) until the
clamps engage in the bottom strainer casing. Important: Lead the connection cable (7) through the cable opening in
the bottom strainer casing (2) and route the cable such that pinching is avoided.
UVC lamp replacement
 K, L, M, N, O
Attention! Breakable glass.
Possible consequences: Injury to your hands caused by cuts.
Protective measures: Handle the quartz glass and UVC lamp with care.
Attention! Ultra-violet radiation.
Possible consequences: Eye or skin injury from burns.
Protective measures:
 Never operate the UVC lamp outside its housing.
 Never operate the UVC lamp in a housing that is defective.
Danger: Ultraviolet radiation.
Do not expose eyes to lamp rays.
Disconnect power before servicing or replacing lamp.
Replace lamp only with lamp rated 7 watts:
Warning: To reduce the risk of electric shock - Connect only to a circuit that is protected by a ground-fault
circuit interrupter (GFCI)
For indoor and outdoor household use
 Open the UVC water housing (see "Opening and cleaning the UVC water housing").
 Remove the self-tapping screw (32).
 Unscrew the clamping screw (34) from the unit head (31) by turning counter-clockwise.
 Pull off the quartz glass (33) and the O-ring (35) while slightly turning the unit head (31).
 Pull out the UVC lamp (36) and replace.
Important: Only use lamps the identification and capacity data of which correspond to the information on the type
plate.
 Check the quartz glass (33) and the O ring (35) for damage.
 Insert the quartz glass (33) including the O ring (35) against the stop in the unit head (31).
 Tighten the clamping screw (34) clockwise up to the stop.
 Turn in and tighten the self-tapping screw (32).
 Close the UVC water housing (see "Closing the UVC water housing").