_____________________________________________________________________
2 2
AC operation
2.2.1 When AC power supply is adopted, the AC/DC adapter supplied
by the company should be used. The basic parameters of the
adapter are as follows:
INPUT:
OUTPUT: DC13.5V⁄5A
2.2.2
The AC/DC adapter will not be able to supple normal DC
output if the input AC voltage is lower than 100V or higher than
240V. At this situation , the DC output line of the adapter must
not be inserted into "POWER INPUT "specified on the power
module of the Fusion Splicer, otherwise it will results in the
damage of fusion splicer.
2.2.3
If lithium battery is arranged in the battery case, the battery
pack will also be charged when the adapter is supplying power.
However, it is recommended that the Fusion Splicer be shut
when charged.
Notes: Do not use power source which does not meet the
requirement of the Company, otherwise the Fusion
Splicer may be burnt, or it will bring other serious
result.
©Copyright Abacanto Digital SA.
AC100-240V 1.8A 50/60HZ
Manual de usuario AD300
AD Instruments
105