_____________________________________________________________________
Note: To ensure high quality of fusion splice, further
calibration is strongly recommended, until three times of
discharge calibration are completed, that is, the "Step II of
discharge calibration completed" message is displayed for
three times; at that time, the discharge calibration interface
will automatically exits.
3.3.6
[Edit Fusion Operation]
The [Edit Fusion Operation] option allows for a number of
important settings for Fusion Option.
A. In the "Splice Mode" menu, press
Fusion Operation] Option, then press
then the "Edit Fusion Operation" menu is displayed. See
the following pictures.
B. Press
in the "Edit Fusion Operation" menu (the yellow words in
the screen are descriptions for the function of the picture);
in the optional screen, Press
cursor to select the option to be changed; then press
to enter the selected option.
C. Press
settings. Finally, press
The 6 optional screens and the parameters of the options are shown in the
©Copyright Abacanto Digital SA.
The screen of "discharge calibration completed"
"Edit Fusion Operation" menu
, and then six optional screens are displayed
or
to return to the previous operation interface.
Manual de usuario AD300
AD Instruments
to select [Edit
to enter, and
and move the
to change the parameters or the
to confirm the changes. Press
133