Preliminary Checks - BFT BOTTICELLI VENERE Instrucciones De Uso

Ocultar thumbs Ver también para BOTTICELLI VENERE:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21
ENGLISH
Thank you for buying this product, our company is sure that you will be more
than satisfied with the product's performance. The product is supplied with a
carefully as they provide important information about safety, installation,
operation and maintenance. This product complies with the recognised
conformity with the following European Directives: 89/336/EEC, 73/23/EEC,
98/37/EEC, 99/05/EEC (and subsequent amendments).
1) GENERAL SAFETY
damage to persons, animals or things.
should be read carefully as they provide important information about
safety, installation, use and maintenance.
bags out of children's reach.
reference.
this documentation could damage the product and be dangerous.
ing from improper use of the product, or use which is different from that
European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subse-
standards as well as the current national standards should be respected
in order to achieve a good safety level.
ing structures (door, gates etc.), as well as from any deformationwhich
might occur during use.
ropean Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent
amendments.
having a contact opening distance equal to or greater than 3,5 mm.
the power supply mains.
closure (doors, gates etc.) and all system components provided with an
earth terminal.
to protect the area from any danger caused by squashing, conveying and
shearing.
and correct operation when other manufacturers' components are used.
by the company.
manual opening operation in case of emergency.
area.
order to avoid unintentional automation activation.
tion system, and always request the assistance of qualified personnel.
is not allowed.
prescribed by the EN 12978 Standard.
higher than 1.5 m.
obstacle 50 mm away from the floor and, if necessary, set it correctly.
12 -
BOTTICELLI VENERE
INSTALLATION MANUAL
2) GENERAL OUTLINE
protruding fully retracting spring-operated overhead doors (fig. 2) and coun-
terweight overhead doors provided with an appropriate towing arm (fig. 4).
The overhead door must not be higher than 3 metres. Its easy installation
allows fast fitting without needing the door to be modified. The irreversible
gearmotor keeps the door locked in the closing position.
3) TECHNICAL SPECIFICATIONS
3.1) Actuator
Power supply:..................................230V~±10%, 50/60Hz single-phase (*)
Motor voltage:........................................................................................24V
Lubrication:......................................................................permanent grease
Towing and pushing force:...................................................................600N
Impact reaction:............................integrated torque limiter on control panel
Manoeuvres in 24 hours:..........................................................................20
Courtesy light:......................................................24V~
-
Motor head weight:.................................................................................5kg
Dimensions:....................................................................................see fig.1
(**)By turning the motor head by 90° (Fig.11) the useful stroke will be 2580 mm.
(***) By turning the motor head by 90° (Fig.11) the useful stroke will be 3180 mm.
4) ACTUATOR INSTALLATION

4.1) Preliminary checks

-
-
its components.
of the door structure.
disable any unnecessary appliances.
4.2) FITTING
by separating the different type of materials (cardboard, polystyrene, PVC,
etc.) according to the national rules in force.
tion the BIN on the ceiling and mark the holes (Fig. 6).
3) Drill the ceiling with a 10-dia. drill bit following the previously made
marks, and insert the Fischer plugs.
4) Secure the track at the base, fig.7 (ref.1-2) and fig.8 (ref.3-4-5).
lintel by means of plugs (Fig.9B).
6) Lift the motor-driven head until everything rests against the ceiling, and
bracket screws).
7)
Fig.10 (always check that the track is level and perpendicular to the cei-
ling).
8) In the case where the track is turned by 90° with respect to the motor
-
9) In the case where the track is made in two halves, see Fig.13; for the
10)
(Fig.14). The distance allowed between track and sectional door is 108
to 166 mm. In case of greater distance, it is necessary to use the brac-
kets and lower the motor; in case of shorter distance, it is necessary to
shorten the towing plate.
11)
5) CHAIN TIGHTENER ADJUSTMENT (BOTTICELLI)
The operator supplied is already calibrated and inspected. Should the chain
tension need to be adjusted, proceed as shown in fig. 15.
-
-