1. Turn the volume control handle and check water
flow from all outlets.
2. Make sure that both filters in the valves are clean.
3. Set the temperature control handle to "104" and
check the temperature to confirm that temperature
is 104° F.
If it is not 104° F, perform the adjustment
according to the instructions in "Adjusting Outlet
Temperature".
CAUTION: To prevent scalding the recommended hot
water temperature is 104° F.
Adjusting Outlet Temperature
1. Turn the temperature control
handle towards hot until the
indicator reads 104° F.
2. Keep the water flowing while
removing the cap, screw and
temperature control handle.
3. Align the 104 mark with the
cover plate and reattach.
4. Reattach the temperature
control handle.
5. Confirm the temperature is
104. If these steps did not
work, follow the instructions in
"Calibrating the valve".

afTeR InSTallaTIon

Control knob
Screw
8
Volume
control
handle
Knob
about 104°F
Mark
"104"
Cap