MESSAGES
Screen
Type of message
display
OcuP
Displayed when attempting to register a code in a position which is
already taken
Skips to the first free position emitting a beep.
rEP
Displayed when attempting to register a code which is already
programmed in another position.
Skips to the position where the programmed code is located, emitting a
beep, and allows the transmitter to be reprogrammed.
no
Displayed when pressing a transmitter which is not programmed in the
unit.
datE
Displayed when a proximity element is used outside its period of validity.
ERRORS
Screen
display
Err.M
Err.M
Err.E
Err.E
Err
IMPORTANT ANNEX
Disconnect the power supply before handing the unit.
In compliance with the European Directive low-voltage electrical equipment, we hereby inform
users of the following requirements:
• For units which are permanently connected, an easily accessible circuit-breaker device must
be built into the wiring system.
• This unit must always be installed in a vertical position and firmly fixed to the structure of the
building.
• This unit must only be handled by a specialised installer, by his maintenance staff or by a duly
trained operator.
• The instruction manual for this unit must always remain in the possession of the user.
• Terminals of maximum section 3,8mm2 must be used for the power supply connections.
BATTERI (Important notice)
This equipment contains a lithium button cell CR2032 3V 40mAH. This button cell
must be removed by a qualified professional and taken to the proper disposal site.

CE DECLARATION OF CONFORMITY

Hereby, FERMAX ELECTRONICA, S.A.U., declares that this EXTRA-500 Ref. 5253, is
in compliance with the essential requirements of Directive RED 2014/53/UE and
Directive RoHS 2011/65/UE. See website www.fermax.com.
FERMAX Avd. Tres Cruces, 133, 46017 Valencia, Spain.
http://docweb2.fermax.com/docs/decconformidad/EN/F05253.pdf
Type of error
Memory error: memory card not inserted or faulty.
Memory error: memory card with incorrect format (from other
equipment). Emits a beep.
Events error: wrong events card.
Events error: events card with incorrect format (from other
equipment). Emits a beep.
Wrong password