6) Service
Have your power tool serviced by a qualified repair person using only identical re-
placement parts. This will ensure that the safety of the power tool is maintained.
1.3
Special safety instructions
Wear proper work clothes, work gloves, safety glasses and safety shoes.
Do not perform any work inside the device! Only trained technical personnel (customer service)
are allowed to work in this area!
It is prohibited to use the TV inspection system for medical uses of any sort!
Do not use force to pull the camera head and reel cable out of the pipe!
The reel cable is rigid and is therefore under mechanical stress! Hold firmly when unwinding
from the reel!
Keep a firm footing.
According to UVV, the minimum distance must be 50 cm (average 64 cm)!
Before each use, check the reel cables for damage. Damaged reel cable must
be replaced! Contact with electrically charged live parts can be fatal!
2
Technical data
Working temperature ...................... -10 ... +50 °C
Storage temperature ....................... -30 ... +50 °C
Dimensions (L x W x H, mm) .......... 360 x 360 x 100
Weight ............................................ 1,0 kg
Camera head diameter ................... ø 25 mm
Slide cable length ........................... 8 m
Slide cable diameter ....................... ø 5,5 mm
Working range ................................ Ø 40 - 100 mm
Protection class camera head ......... IP 68
Included in delivery: ROCAM
3
Function of the Unit
3.1
Overview
1
Camera head
2
Bending spring
3.2
Working notes
- Do not bend the reel cable! The cable may break!
- Do not pull the reel cable over sharp edges! The cable may become damaged!
3.3
Replace the reel
Switch off ROCAM
Installing ROCAM® 4 vertically. Front flap must be closed here!
Remove camera head (1) from the holder and take the reel cable (3) carefully out of the
guide hook.
12
Always set the pipe cable next to the "axis"; otherwise there is a risk of injury!
®
4 – 8m Minimodul , manual.
®
4 before replacing the reel!
3
Reel cable
4
Reel
ENGLISH
(A)