Operating instructions
Always observe the operating instructions and
"Important operating notes" prior to starting! The vehicle
owner is responsible for correct operation of the appliance.
The installer or vehicle owner must apply the yellow sticker
with the warning information, which is enclosed with the ap-
pliance, to a place in the vehicle where it is clearly visible to all
users (e.g. on the wardrobe door)! Ask Truma to send you a
sticker, if necessary.
a = Control knob
b = Flame observation window
c = Piezo ignitor (Model: Trumatic S 2200 P)
d = Automatic ignitor with battery compartment
(Model: Trumatic S 2200)
e = Type plate
f = Ignition and low setting
g = High setting
h = Heater switched off
In appliances with exhaust gas connection on the right hand
side, the parts are arranged on the opposite side respectively.
Switching on the Trumatic S 2200 P with piezo
ignitor
1. Remove cowl caps (with wall cowl)!
2. Turn on gas cylinder and open quickacting valve in the gas
supply line.
3. Adjust control knob (a) to the ignition symbol (f) and press
down. At the same, keep operating the piezo ignitor (c) rapidly
until the flame ignites.
Keep the control knob (a) pressed down for a further 10 sec-
onds to allow the safety pilot to operate.
4. Watch through the flame window (b) for another 10 sec-
onds to make sure that the flame does not go out through air
in the supply pipe (caused by the valve being closed or chang-
ing the cylinder).
Always wait at least 2 minutes before attempting
to re-ignite, otherwise risk of blow back (misfiring)!
This also applies if a working heater goes out and has to be
relit.
5. Let the heater run approx. 1 minute in the ignition posi-
tion (f), then switch to "high" (g).
14
If the gas supply line is full of air, it may take up to a minute
before the gas is available for combustion. During this time,
keep holding the control knob in depressed position and con-
tinuously actuate the piezo ignitor until the flame ignites.
6. The heat output can be adjusted in a stepless manner at the
control knob (a) between the low setting (f) and high setting (g).
Switching on the Trumatic S 2200 with
automatic ignitor
Before igniting for the first time, make sure that a bat-
tery has been inserted (see notes under "Changing Battery
on the automatic ignitor")!
1. Remove cowl caps (with wall cowl)!
2. Turn on gas cylinder and open quickacting valve in the gas
supply line.
3. Adjust control knob (a) to ignition symbol (g) and press
down. Igniting takes place in this position automatically
(sparking is audible) until the flame is ignited.
Keep the control knob pressed down for a further 10 seconds
to allow the safety pilot to operate.
In event of faults always wait 2 minutes before
re-igniting!
4. If the flame goes out again, the flame igniting is repeated
straight away during the closing time of the safety pilot
(approx. 30 seconds).
5. Let the heater run approx. 1 minute in the ignition position,
then switch to the "high" setting (g).
If the gas supply line is full of air, it may take up to a minute
before the gas is available for combustion. During this time,
hold the control knob in depressed position until the flame
ignites.
If there is no flame, the automatic ignitor keeps on operating
until the control knob (a) is switched off (h).
6. The heat output can be adjusted in a stepless manner at
control knob (a) between the low setting (f) and high setting (g).
Switching off
Set control knob (a) to "0" (automatic ignitor is switched off at
the same time). If the appliance is not being used for a longer
period, close the quickacting valve in the gas supply line and
turn off gas cylinder.
To ensure even and rapid warm air distribution as well as
reduction of surface temperatures on the appliance, we
recommend you operate the heater with the Trumavent warm
air system.