E N G L I S H
Also refer to the table below.
2
Conductor size (mm
)
0.75
1.00
1.50
2.50
4.00
Voltage
Amperes
115
0 - 2.0
2.1 - 3.4
3.5 - 5.0
5.1 - 7.0
7.1 - 12.0
12.1 - 20.0
230
0 - 2.0
2.1 - 3.4
3.5 - 5.0
5.1 - 7.0
7.1 - 12.0
12.1 - 20.0
Assembly and adjustment
Prior to assembly and adjustment
always unplug the tool.
Forward/reverse slider (fig. B)
• To select forward or reverse rotation, use the
forward/reverse-switch (3).
Always wait until the motor has come
to a complete standstill before
changing the direction of rotation.
Inserting and removing a drill bit (fig. A)
Keyless chuck
• Open the chuck by turning the sleeve (5)
counterclockwise and insert the bit shank.
• Tighten firmly by turning the sleeve clockwise.
• To remove the bit, proceed in reverse order.
Chuck removal (fig. C)
• Open the chuck jaws as far as possible.
• Tighten an Allen key into the chuck and strike it
with a hammer as shown.
12
Cable rating (Amperes)
6
10
15
20
25
Cable length (m)
7.5
15
25
30
45
Cable rating (Amperes)
6
6
6
6
6
6
6
6
15
6
6
10
15
20
10
10
15
20
20
15
15
20
25
25
20
20
25
-
6
6
6
6
6
6
6
6
6
6
6
6
10
10
10
10
10
15
15
15
15
15
20
20
20
20
20
25
Instructions for use
• Always observe the safety instructions
• Be aware of the location of pipework
• Apply only a gentle pressure to the tool.
60
Prior to operation:
6
10
• Insert the appropriate bit.
15
• Mark the spot where the hole is to be drilled.
20
25
Switching on and off (fig. A)
-
• To run the tool, press the variable speed switch
-
-
(1). The pressure exerted on the variable speed
6
6
switch determines the tool speed.
6
6
• For continuous operation, press and hold down
15
the variable speed switch, press the lock-on
15
button (2) and release the switch.
20
• To stop the tool, release the switch.
-
• To stop the tool in continuous operation,
press the switch briefly and release it.
Always switch off the tool when work is finished
and before unplugging.
Consult your dealer for further information on the
appropriate accessories.
Maintenance
Your BERNER Power Tool has been designed to
operate over a long period of time with a minimum of
maintenance. Continuous satisfactory operation
depends upon proper tool care and regular cleaning.
Lubrication
Your power tool requires no additional lubrication.
Cleaning
Keep the ventilation slots clear and regularly clean
the housing with a soft cloth.
and applicable regulations.
and wiring.
Excessive force does not speed up
drilling but decreases tool performance
and may shorten tool life.