OBJ_DOKU-4441-001.fm Page 10 Monday, October 16, 2006 9:22 AM
Technical Data
Magnetic drill stand
Article number
Rated power input
Holding force of the
magnet
Max. drilling dia.
(GBM 32-4, MK3 tool
holder)
– Twist drill bit
– Core bit
Drill stroke, max.
Diameter of drill fixture
Weight according to
EPTA-Procedure
01/2003
Protection class
Please observe the article number on the type plate of your
drill stand. The trade names of individual drill stands may vary.
Declaration of Conformity
We declare under our sole responsibility that this prod-
uct is in conformity with the following standards or
standardization
documents:
DIN VDE 0580 according to the provisions of the
directives 73/23/EEC, 89/336/EEC, 98/37/EC.
06
Dr. Egbert Schneider
Dr. Eckerhard Strötgen
Senior Vice President
Head of Product
Engineering
Certification
15.09.2006, Robert Bosch GmbH, Power Tools Division
D-70745 Leinfelden-Echterdingen
Assembly
Inserting the Drill
Remove the auxiliary handle from your drill, if required
(see the operating instructions of the drill).
Loosen screw 5 using an Allen key. Insert the drill with
the drill collar from above into the drill fixture 4 to the
stop. Mount screw 2 in order to connect the drill with
the side holder 3. Hand-tighten screw 5 using an Allen
key.
Check the tight seating of the drill in the drill
fixture.
10 | English
Operation
GMB 32
PROFESSIONAL
0 601 193 0..
W
95
kN
25
Starting Operation
mm
32
mm
12 – 60
mm
223
mm
65
Switching On and Off
kg
26
/I
Push the magnet On/Off switch 8 upward and check if
the drill stand adheres to the workpiece surface.
EN 61029,
To start the drill, press the motor On/Off switch 6 to
position "I".
Note: The drill can only be started when the magnet
has already been switched on.
To switch off the drill, press the motor On/Off switch 6
to position "0".
Wait until the drill has come to a complete stop before
pushing the magnet On/Off switch 8 downward in
order to switch the magnet off.
Restarting protection
The restarting protection prevents uncontrolled starting
of the drill after the power supply is interrupted.
For restarting the operation, press the motor
On/Off switch 6 to position "I".
Note: The magnet automatically switches on after
resumption of the power supply.
Pull the plug from the socket outlet and/or
remove the battery before carrying out adjust-
ments on the power tool or replacing acces-
sory parts. Unintentional starting of drills is the
cause of some accidents.
After each adjustment on the drill stand,
retighten the bolts and locking handles.
Observe correct mains voltage! The voltage of
the power source must agree with the voltage
specified on the nameplate of the machine.
Power tools marked with 230 V can also be
operated with 220 V.
Insert the mains plug of the drill only into
socket outlet 7. Switch the drill on and lock
the On/Off switch of the drill with the lock-on
button. Otherwise, the drill cannot be switched on
or off via the motor On/Off switch 6 on the drill
stand.
1 609 929 K50 • 16.10.06