LIFT WITH MECHANICAL SAFETY DEVICES
The controls for using the lift are:
Main switch (10)
The main switch has two positions:
Position 0: the electrical circuit of the lift is not powered; it is possible to secure the
switch using a metal padlock to prevent its use. Position 1: the electrical circuit of the
lift is powered.
Up button (5)
Press the black "up" button to move the lift up. The lift rises to the up software limit
switch. The buzzer sounds to confirm when the lift has reached the limit switch.
Down button (6)
"
"
Press the
down
button (6) to lower the lift. The lift briefly moves up to disengage the
safety devices before lowering.
If the lift is already at the upper limit switch, it immediately moves down without rising first.
The lift lowers as far as the down limit switch is reached (approximately 400 mm
from the floor). The buzzer sounds to confirm when the lift has reached the limit
switch.
NOTE: Press the end of travel button (7) to lower the lift fully. End of travel /
safety lock button (7)
Press the end of travel/safety lock button (green) to lower the lift until it engages the
mechanical safety device.
NOTE: This button is also used to lower the lift fully once it has reached the down
limit switch.
Internal acoustic warning
signal/buzzer Warning
light (9)
During the final travel, make sure that the safety area is free
Manual realignment must always be performed with the lift
unloaded (with no vehicle)
8.1.1 Controls
During the final travel, make sure that the safety area is free
WARNING.
118