The control unit "DA.93AM" can be used with motors having a total power not exceeding 750W.
Installation instructions.
a)
The electric installation and the operating logic must comply with regulations in force.
b)
It is advisable to keep the power cables (motor, power supply) detached from the control cables (push-but-
tons, photocells, radio). In order to avert any possible interference it is recommended to provide for and use
two separate sheaths (see EN 60204-1 15.1.3).
c)
Before powering the unit, check again all connections which have been carried out.
d)
Check that the presettings of the Dip-Switches are correct.
e)
When the unit is powered, the LED "POWER" must be lit; in the negative, check that fuses are in
good condition and that 230Vac 50Hz power supply is present between terminals 1 and 2 (INPUT 230VAC
- keep to line/ground connection).
f)
The N.C. inputs not used must be connected to the common "+V".
Terminal No.
Function
(1,2)
INPUT 230VAC
(3,4,5)
C O M / A P R E /
CHIUDE M1
(6,7,8)
C O M / A P R E /
CHIUDE M2
(9,10)
LAMP230
(11,12)
CORTESIA
(13,14)
OUT 24VAC
(15,16)
ELS
(17,18)
SCA
(19,20)
+V
(21)
FTCA
(22)
FTCC
(23)
FCA1
(24)
FCA2
(25)
FCC
(26)
STOP
(27)
PED
(28)
P.P.
(29)
APRE
(30)
CHIUDE
(31,32)
ANT.
(33,34)
RX 2CH.
J1
RTX
JP1
SPUNTO
The power of motors can be controlled through the 5-step commutator "MOTOR POWER".
6
DA.93AM Control unit with microcontroller
Input/Output functions
Description
Control unit 230Vac 50 Hz power supply (respect phase/neutral wire
position).
Connection to the corresponding 230Vac 50 Hz motor terminals (delayed
in closing) (the earth wire (green/yellow) must be connected).
Connection to the corresponding 230Vac 50 Hz motor terminals (delayed
in opening) (the earth wire (green/yellow) must be connected).
Connection to the 230Vac blinker.
Connection to the 230Vac courtesy lamp.
24Vac auxiliary power supply output (1Amax.).
12Vac output for electric lock.
24Vdc "Gate open warning light" contact (250mA).
Function for the "Gate open warning light" contact.
•If the gate is closed, the warning light is turned off.
•If the gate is opening, the warning light flashes slow (about 1Hz).
•If the gate is closing, the warning light flashes fast (about 2Hz).
•If the gate is open, or the race is interrupted manually (PP - STOP), the
warning light remains turned on.
N.B.: The led is driven by a relay, thus the commutation can be normally
heard during the normal function of the control board.
Common connection to all the control inputs.
Opening photocell receiver input (n.c. contact) (photocell far from the
gate).
Closing photocell receiver input (n.c. contact) (photocell near the gate).
Limit switch input - M1 motor opening (n.c. contact).
Limit switch input - M2 motor opening (n.c. contact) - opening delay.
Limit switch input - M1 and M2 motor closing (n.c. contact).
STOP button input (n.c. contact).
PEDESTRIAN button input (n.o. contact).
STEP-by-STEP button input (n.o. contact).
OPEN button input (n.o. contact).
CLOSE button input (n.o. contact).
Input of radio board antenna
Radio board 2nd channel contact (n.o. contact).
Connector for receiver board of the remote control
Selection jumper, "PICKUP" of starting motors
1) Closed : enabled pickup
2) Open : inhibited pickup