6
Safety Notes
6 Gloves should be worn during installation to prevent crushing and cutting
injuries.
6 The arm of the shower head is intended only to hold the shower head. Do not
load it down with other objects!
6 Children as well as adults with physical, mental and/or sensoric impairments
must not use this shower system without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from using this shower system.
6 Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
6 The product may not be used as a holding handle. A separate handle must be
installed.
6 The shower system may only be used for bathing, hygienic and body cleansing
purposes.
6 The hot and cold supplies must be of equal pressures.
Installation Instructions
• The fitting must be installed, flushed and tested after the valid norms.
• The installation dimensions stated in this installation instructions are ideal for peo-
ple of approximately 1800 mm in body height. The dimensions can be altered if
required. In this case you will have to attend to the minimum height of 2330 mm
from shower tray floor, and alter all the required measurements as necessary.
• Where the contractor mounts the product, he should ensure that the entire area of
the wall to which the mounting plate is to be fitted, is flat (no projecting joints or
tiles sticking out), that the structure of the wall is suitable for the installation of the
product and has no weak points. The enclosed screws and dowels are only suita-
ble for concrete. For another wall constructions the manufacturer's indications of
the dowel manufacturer have to be taken into account.
• The filter insert (A) must be used to ensure the standard flow rate and to protect
the hand shower against incoming dirt by pipework. Do you want a larger water
flow rate, then you must use the filter packing (B) instead of the filter insert (A).
Incoming dirt leads to defects or/and can damage parts of the hand shower;
such caused faults voids all liability and guarantee claims.
• In case of emergencies, the lower part of the pipe can be shortened by means of
a fine saw.
Fault
Insufficient water
Crossflow, hot water being forced into cold water
pipe, or vice versa, when mixer is closed
Spout temperature does not correspond with
temperature set
Temperature regulation not possible
Instantaneous heater didn't work with thermostat
4
English
Cause
- Supply pressure inadequate
- Filters are dirty (96922000)
- Shower filter seal dirty
- Backflow preventers dirty or leaking
- Thermostat has not been adjusted
Hot water temperature too low
- thermo cartridge calcified
- Flow limiter in handshower isn't removed
- Filters are dirty
- Non return valve hasn't moved back
Assembly see page 10
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Centre distance:
Connections G 1/2:
anti-pollution function
Symbol description
Do not use silicone containing acetic acid!
Safety Function (see page 13)
The desired maximum temperature for example max. 42º C can be pre-
set thanks to the safety function.
Adjustment (see page 13)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the
output differs from the temperature set on the thermostat.
Maintenance (see page 15)
The non return valves must be checked regularly according to DIN EN
1717 in accordance with national or regional regulations (at least once
a year).
To guarantee the smooth running of the thermostat, it is necessary from
time to time to turn the thermostat from total hot to total cold.
Dimensions (see page 14)
Flow diagram
(see page 14)
overhead shower
Hand shower
Operation (see page 17)
Cleaning (see page 16) and enclosed brochure
Spare parts (see page 18)
Remedy
- Check water pressure (If a pump has been installed
check to see if the pump is working).
- Clean filter in front of the mixer and on the MTC-
thermo cartridge
- Clean filter seal between shower and hose
- Clean backflow preventers, exchange if necessary
- Adjust thermostat Increase hot water temperature to
42 ºC to 65 ºC
- Exchange thermo cartridge
- Remove flow limiter
- Clean the filter / exchange filter
- Exchange non return valves
max. 1 MPa
0,15 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
150 mm
cold right - hot left