Troubleshooting
Problem
Voltage is present but
the compressor doesn't
run
Electric circuit between
the pins in the compres-
sor interrupted
Poor cooling, increase in interior temperature
Problem
Compressor runs for a
long time/continuously
Compressor does not
run often
Unusual noises
Problem
Loud humming
32
Possible cause
Ambient temperature too high
Insufficient ventilation
Condenser is dirty
Defective compressor
Possible cause
Ambient temperature too high
Insufficient ventilation
Condenser is dirty
Faulty fan
Battery capacity exhausted
Possible cause
A component of the refrigerant circuit
cannot move freely (touching the
wall)
There is a foreign object stuck
between the cooling unit and the wall
Fan noise
Remedy
Move the refrigerator to
another location
Clean the condenser
Replace the compressor
Remedy
Move the refrigerator to
another location
Clean the condenser
Replace the fan
Charge the battery
Remedy
Bend the component
carefully away from the
obstruction
Remove the foreign
object