If it gives out continuous beeps when connecting the battery, the electronic control is
disconnected or poorly connected in the control panel.
E0 - Return air sensor failure.
- Low battery, less than 22.8V.
E2 - Condenser or blower fan failure.
E3 - Compressor failure (Causes: engine, wiring, connector, lack or excess of charge).
E5 - Compressor electronic module failure due to heating.
E6 - Anti-freeze sensor failure.
To activate this function, keep the On/Off
F6, and then release the key to directly enable ºF. To return to ºC, keep the
control panel pressed down with the display flashing C
press the
+
key on the control panel.
!
In some cases of mistake message, to swith off the unit keep the On/Off button
pushed till the screen switches off.
!
If, during operation, the display and the equipment go off, the cause may be that the
communication cable is disconnected or cut, that the communication cable cut-out
has blown, that the power supply cable has failed, or that the power supply cable is
disconnected or cut.

Error messages

F6 Function: ºF Selection
Important
Important
8
key pressed down until the display shows
, when it stops flashing,
®
-
key on the