Drill the window frame in the points marked with the diameters indicated in the drawings and clean the
edges of any burr.
▪
Check (by overlapping them) that the actuator is positioned correctly and the hook (in the closed
position) is aligned with the pawl of the closed sliding accessory.
▪
Check that the electrical cable path is free of obstacles; otherwise eliminate them.
▪
Now the window frame can be assembled.
8.2.5.
•
Check that the cable path has been prepared beforehand and all the holes have been drilled.
•
Position the actuator on the window frame and secure it with the screws provided.
•
Make the electrical connections following the instructions and diagram provided below in Chapter 9.
"Electrical connection".
•
Complete the path of the cables and finish making the electrical connections.
The device requires a voltage of 24V ═ (DC).
Higher voltage may destroy the motor.
•
Perform a final test and verify that the device operates correctly on the window frame, moving the pawl
of the sliding accessory sideways.
•
Power the device and move the pawl to the Open position; the hook of the actuator must slide towards
the center of the machine.
•
Close the sash of the window or door.
9. ELECTRICAL CONNECTION
The device is equipped with power supply cables constructed in compliance with current safety standards,
restrictions for protection against radio interference and according to that required by standard EN 12101-2
– Smoke and heat exhaust ventilators.
Warning if the cables require extension:
-
use the same type of cable;
-
prepare the correct cross-section of the cables;
-
to avoid connection errors, use the same coloring of the wires.
For the wiring and electrical connection, follow the diagrams below.
Connection of a SLIM-LOCK with one chain actuator.
External assembly
+
2
2
24V