MAINTENANCE AND CHANGE OF SIZE (fig. f5-f6-f7)
The extended utilization of the riveting tool can cause the slipping
of the clamps on the nail due to the deposited impurities. For this
reason, it is necessary to lubricate the clamps after having cleaned
them with benzine or derivates. However, if clamps are worn out
and as a consequence their working is jeopardized, replace them.
First remove the head which carries the nozzle Q, by means of
a standard spanner of 27 mm.
Once you remove the tube carrying nozzle, use two commercial
wrenches (17 and 16 mm) to remove the cone R from which the
clamps S will be removed.
To replace the nozzle T, we recommend using the wrench provided
and installing the nozzle previously removed from the riveting
tool on it, so as not to lose it.
WARNING!
The riveting tool must be shut off during the
above operations.