2 PRODUCT DESCRIPTION
NET24N is a universal control panel for DEA System 1 or 2 24V
The main feature of this control board is its ease of configuration of inputs and outputs according to any needs thus ensuring adapta-
bility to any type of automation. It is therefore easy to set up and exclude all unnecessary functions.
3 TECHNICAL DATA
Power supply (V)
Rated power transformer (VA)
Fuse F1 (A) (transformer)
Batteries
Fuse F2 (A) (batteries input)
Outputs 24V
motors (maxi-
mum output current) (A)
Auxiliaries power supply output
Stabilized power supply output for
safety devices
"Warning" output
Electric lock output
Flashing light output
Operating temperature range (°C)
Receiver frequency
Transmitters type of coding
Max remote controllers managed
* Values for STOP with boom ≥ 6 m.
Livi 5/24 - Livi 8/24
Rev
Livi 550PL
TYPE 00
80 VA
250 VA
120 VA
(230/22V)
(230/22V)
(230/22V)
1A
2x
12V 1,3A
1x 5A
1x 10A
Warning: The above values are calculated by taking the maximum power supplied by the respective processors.
In absolute terms, the maximum current for each output should not exceed 10A when using a single motor and
7A when using 2 motors.
HCS fix-code - HCS rolling code - Dip-switch
Geko
Look - Mac - Sting
Livi 902/24
Pass - Stop
Livi 905/24
operators automations with or without encoder.
TYPE 01
TYPE 02
ANGOLO
Ghost 100/200
LOOK - MAC - STING
LIVI 500/502
550PL
230 V ~ ±10% (50/60 Hz)
150 VA
(230/22V)
2A
2x
12V 1,3A
15A
2x 5A
24 V
(24V_AUX + 24V_ST = max 200mA)
+24 V
max 15 W
24V
max 5W or max 1 art. 110
24 V
max 15W
-20÷50 °C
433,92 MHz
100
Livi 500 - Livi 502
*
If you are not using DEA operators, set the parame-
ter "Selection type of operator" to the closer value as
family type and performances.
TYPE 03
STOP
4÷5 m
≥ 6 m
150 VA
250 VA*
(230/22V)
(230/22V)
3,15A*
2x
12V 4A
2x 5A
2x 7A*
Ghost 100 - Ghost 200
33