TYPE
TYPE
TYPE
TYPE
00
01
02
03
• 000: "ram blow" deactivated
• 001: "ram blow function" activated
• >001: "ram blow" periodic (X*1 min)
(2...................................255)
• 000: "reversal function"
• 001: "step by step function"
• 000: photocell enabled while closing and when gate is
stopped
• 001: photocells always enabled
• 002: photocells enabled only while closing
• 003: as 000 but with "close immediately" enabled
• 004: as 001 but with "close immediately" enabled
• 005: As 002 but with "close immediately" enabled
• 000: "fix warning light"
• 001: "flashing warning light"
• >001 : "courtesy light" off delay
(2sec..................255sec)
• 000: Stop when opening on a memorized point
• 001: Stop when opening on the end of stroke
• 000: "soft start" deactivated
• 001: "soft start" activated
• 002: "long soft start" activated
• 003: "settable soft start" on (Type 2 only)
• 000: complete reversal on obstacle
• >000: duration of reversal on obstacle
(1sec.................10sec)
• 000: complete reversal on obstacle
• >000: duration of reversal on obstacle
(1sec.................10sec)
• 000: facilitating release disabled
• >000: facilitation activated with release time equal to:
(1x25ms......20x25ms)
(1x25ms.................40x25ms) (only Type 0)
1..................255 (motors with encoder)
1%...............100% (motors without encoder)
0...................................255
55