Electrical Connections - Dea NET24N Instrucciones De Uso

Ocultar thumbs Ver también para NET24N:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 123

5 ELECTRICAL CONNECTIONS

Execute the wiring following the directions of table 1 and diagrams.
WARNING For adequate electrical safety, keep low safety voltage wires (controls, electro-locks, antenna, auxiliary power) clearly separate
from 230V ~ power wires (minimum 4 mm in air or 1 mm via supplementary insulation) placing them in plastic raceways and securing
them with adequate clamps near terminal boards.
WARNING For connection to the mains, use a multipolar cable having a minimum section 3x1,5 mm² and complying with the current
regulations. For connecting the motors, use a minimum cross section 1,5 mm² cable and complying with the current regulations. As
an example, if the cable is out side (outdoor), must be at least equal to H07RN-F, whereas if it (in a raceway), must be at least equal to
H05VV-F.
WARNING All wires must be striped and unsheathed in the immediate vicinity of terminals. Keep wires slightly longer to subsequently
eliminate any excess.
WARNING To connect the encoder to the control panel, use only a dedicated cable 3x0,22mm
3-4
22 V ~ transformer power supply input
5-6
24 V
battery power supply or photovoltaic accumulator Green Energy input (follow carefully polarity indications).
7-8
Operator 1 output
9
Connection of motors metallic parts
10-11
Operator 2 output (if present)
24 V
max 15 W output for open gate fix warning light (if P052=0), flashing (if P052=1) or courtesy light (if
12-13
P052>1)
"Boost" output for electric-lock, max 1 x art. 110 (if P062=0), 24V pulse output, max 5W (if P062=1), step
14 (-)
by step (if P062=2), electro-brake output for not self-locking operators (if P062=3), output for electric-lock
14-15
power supply via external relay (if P062=4), output for electro-magnets power supply for barriers (ifP062=5)
15 (+)
or temporized output (if P062>5).
16-17
24 V
Flashing light output max 15W art. LED24AI
18 - IN_6
Input 6
19 - Com
20 - IN_5
Input 5
21 - Com
22 - IN_4
Input 4
23 - Com
24 - IN_3
Input 3
25 - Com
26 - IN_2
Input 2
27 - Com
28 - IN_1
Input 1
29 - Com
30
Aerial signal input
31
Ground aerial input
32 (+)
32-33
24 V
33 (-)
1 (-)
1-2
Stabilized 24 V
2 (+)
Encoder selection Jumper:
J5
J9
•A position = operators with encoder (remind to set P029=0)
B
A
B
A
•B position = operators without encoder (remind to set P029=1)
Table 1 "terminal board connections"
TYPE 00
TYPE 01
If unused, short circuit
(FCC 1)
(STOP)
N.C.
N.C.
(FCA 1)
(PHOTO 2)
N.C.
N.C.
( PHOTO 1)
(PHOTO 1)
N.C.
N.C.
(SAFETY)
(SAFETY)
N.C.
N.C.
(PEDESTRIAN)
(PEDESTRIAN)
N.O.
N.O.
(START)
(START)
N.O.
N.O.
power supply output for auxiliary devices
power supply output for tested safety devices
.
2
TYPE 02
TYPE 03
(NONE)
(NONE)
N.O.
N.O.
(NONE)
(NONE)
N.O.
N.O.
(STOP)
(NONE)
N.C.
N.O.
(SAFETY)
(NONE)
N.C.
N.O.
(PHOTO 1)
(PHOTO 1)
N.C.
N.C.
(START)
(START)
N.O.
N.O.
(AUX + ST)
=
max 200mA
35

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido