Configuration of settings.
Introduce the two digits of its position, you will hear a beep and then you need to enter the
desired value (1, 2, 3 or 4 digits, depending on the setting). If the value is correct you will
hear a confirmation tone (beep-beep) and the new value will have been saved. If it was
incorrect you will hear the error sound (beep-boop).
Position +
Possible values
01...16 (beep)
1, 2, 3 or 4 digits (beep-beep)
Examples
Position +
Possible values
09 (beep)
1128 (beep-beep)
01 (beep)
02 (beep-beep)
To leave the programming mode you need to press 'A' when introducing the position number
of the menu. It will also automatically exit after 60 seconds without the need to press any
key, generating a beep-beep tone.
NOTES:
- If trying to assign the same programming code as the lock-release code, it is not allowed
and a call error tone sounds (beep-bop).
- To deactivate the opening code you must enter the value AAAA in position 08
- When configuring a zero value in «Volume Monitoring" you mute the button, call, and
other monitorings of the outdoor panel.
Resetting the programming access code (if the previous one is forgotten).
En If you have changed the programming access code (if the previous one is forgotten), you
may restore the default code.
Carry out the following steps:
1. With the power supply disconnected, short circuit the «Bs» and «-» (negative) amplifier
terminals (or press the exit button when one exists).
2. Maintaining the short-circuit induced above, connect the system's power supply (at this
point it will no longer be necessary to maintain the short circuit or hold down the button).
The default code is now restored: 4444.
NOTE:
- If you happen to assign the door´s lock-release code the same code as that of the default
programming entrance code, when restoring the programming access you immediately
deactivate the lock-release access code. This is because you can not have the same code
in both programming parameter fields
Configuring the street panel for BUTTONS connected to a keypad.
You can configure the push button panel alone, see ANNEX: Voice assisted configuration
in button panels code 970048 at www.fermax.com..
You can also configure it by temporarily connecting a keypad ref. 7439.
See «Configuring the Direct Panel» on the previous page.
See the keypad connection diagram on the next page.
Carry out the following steps:
1. With the power disconnected remove the CN1:
Comment
Digits depending on chosen setting
Comment
Change of programming code to 1128
Change of lock release activation time to 2
seconds
Pag 43