6. Verify the hole diameter you will have to drill on the connection box according to the
strain relief you wish to use, according to TAB 3: for PG 16, hole diameter is 23 mm.
7. Drill the connection box on the marked spot with a hole diameter according to the previ-
ous point (Fig. 3/a-b).
8. Fix the strain relief to the connection box with the right nut (Fig. 3/c-d).
9. Insert the cable through the strain relief and connect the power wires (Fig. 3/e-f).
10. Tighten the strain relief (Fig. 3/g).
11. Lock the connection box with 4 proper screws (Fig. 3/h).
5. USE OF THE PRODUCT
• This product is not supplied with any switch or device for controlling temperature and must
be regulated by appropriate devices that should be contemplated in the plant construction
phase (E.g. differential switches and circuit breakers).
• In versions with 2 or 3 resistances there is the possibility of designing different power supply
circuits, so it is possible to activate the product partially when less heating is needed. In the
versions with 3 resistances, for example, it is recommended to have a circuit supplying the
central element (Phase L2) and another for the side elements (Phases L1 and L3) so it is
possible to use 1/3, 2/3 or 3/3 of the available power, as needed.
• Attention! After the initial installation and during the first few hours of operation, the product
may give off an unpleasant smell and/or a small amount of fumes. This is caused by the
presence of traces of substances used in the production process and it is not a defect or
product malfunction nor does it pose any danger to the safety and health of users.
6. MAINTENANCE
• This product requires no special maintenance.
• It is recommended to check that the device is cold and disconnected from the power sup-
ply before any intervention.
• If the appliance needs repairing, please contact an authorised Technical Service.
12