4.2 — Service Schedule
ATTENTION: All service work must be performed by a qualified service person only.
System Component
X = Action
R= Replace as Necessary
* = Notify Dealer if Repair is Needed
Fuel
Fuel lines and connections*
Lubrication
Oil level
Oil
Cooling
Enclosure louvers
Battery
Remove corrosion, ensure dryness
Clean and tighten battery terminals
Check charge state
Electrolyte level (unsealed batteries only)*
Engine and Mounting
Air cleaner
Spark plug
Valve Clearance
General Condition
Vibration, Noise, Leakage*
* Contact the nearest Dealer for assistance if necessary.
** Change oil after the first 20 hours of operation or 1 month. Continue to check at intervals of 100 hours or 6 months, whichever occurs first. Severe duty oil
drain intervals: In cold weather conditions (ambient below 40
of water in the oil. If the unit will be operated continuously in hot ambient conditions (ambient above 85
environment change the engine oil every 3 months or 50 hours of operation to prevent oil breakdown.
*** Check valve clearance after the first 20 hours of operation. Continue to check at intervals of 300 hours.
4.2.1 — Maintenance Log
1.
Battery inspection and charge check (recommended every year (1) for the life of the battery)
NOTE: Check electrolyte level (unsealed batteries only) every 6 months.
Dates Performed:
2.
Oil, oil filter and air filter replacement (recommended after the first 20 hours after installation and every 100 hours or 6 months, whichever
occurs first)
NOTE: Spark plug replacement (recommended every 1 year or 300 hours, whichever occurs first).
Dates Performed:
18
Procedure
Change
Inspect
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
º
º
F/4.4
C) change engine oil every 6 months or 50 hours of operation to prevent accumulation
Clean
M or 24 hours of continuous operation
6 M or 100 hours of operation**
X
X
X
X
3 M / 50 hours - clean / 1 Y / 300 hours - replace
6 M or 100 hours - inspect / 1 Y or 300 hours - change
1 Y or 300 hours***
º
º
F/29.4
C) or operation in an extremely dusty or dirty
Automatic Standby Generator Owner's Manual
Frequency
W = Weekly
M = Monthly
Y = Yearly
M
W
Y
Y
Y
Every 6 M
M