DIP Switch Settings

1 2
3 4 5 6
7 8
DIP 1: LEDs operation
On: LEDs enabled
Off: LEDs disabled
DIP 2-3: PIR Detection Sensitivity
Sensitivity
Low
Mid
Normal
Maximum
DIP 4: Auxiliary relay control
ON: Enabled
OFF: Disabled

Detection Range Adjustment

Slide the moving PIR to the desired
position, see figure 6.
The range of the lower detection area
determines the detection range.
The upper PIR is fixed and its detection
area is parallel to the ground at all times.
The lower detection area changes from
2m to 12m depending on the location of
the moving PIR. Therefore, the detection
range is established according to the
location of the lower PIR since both the
upper and the lower PIR should be
triggered in order to activate an alarm.
8
Factory
Default
DIP2
DIP3
Off
Off
Off
On
On
Off
On
On
WatchOUT PIR Installation Manual
DIP 5: Used to define the auxiliary relay operation
following an alarm condition, depending on
Day/Night time (defined by 24 Hours / Night
Photocell)
ON (Night): Auxiliary relay is activated only
during nighttime.
OFF (24 Hours): Auxiliary relay is activated
24 hour
DIP 6-7: Defines the time duration that the auxiliary
relay is activated
Activation Time
2.2 seconds
2.0 Minutes
4.0 Minutes
8.0 Minutes
DIP 8: Red LED /3 LED
ON: Red LED only
OFF: 3 LEDs
Switch 6
Switch 7
OFF
OFF
OFF
ON
ON
OFF
ON
ON
Figure 6