Dip Switch Settings; Microwave Adjustment; Walk Test - Risco WatchIN Serie Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

SET/
This input enables to control Anti-masking and LEDs operation in accordance to
UNSET
the system status, Set (Arm) / Unset (Disarm).
While the system is armed, this feature prevents an intruder from gaining
knowledge of the detector's status and disables Anti-masking detection.
System Status
Set (Arm)
Unset (Disarm)
DIP 7 is ON (Anti masking enabled)
*
** DIP 1 is ON (LEDs enabled) and LEDs ENABLE input terminal is enabled
(+12V OR no terminal connection)

DIP Switch Settings

ON
1
2
3
4
5
6
7
8
DIP 1: LEDs operation
On: LEDs Enabled
Off: LEDs Disabled
DIP 2-3: Detection Sensitivity
Sensitivity
DIP2
Low
Mid
Normal (Default)
ACT(Anti-Cloak™
Technology)

Microwave Adjustment

Adjust Microwave coverage area by using the trimmer on the PCB.

Walk test

Two minutes after applying power, walk test the protected area to
verify proper operation.
For installations on uneven surfaces slide the PCB inside the internal
base to the appropriate setting according to the desired height (2.4m,
3.0m, 3.7m) as printed on the bottom left corner of the PCB or use
the standard swivel accessory.
For reducing the detection range, slide the PCB up or tilt the swivel
down.
Input Status
12V or no connection
DIP 4: Alarm condition
Factory
Default
DIP 5: Detector's optics
9 10
DIP 6: Red LED /3 LED
DIP 7: Anti masking operation
DIP3
Off
Off
DIP 8: Vibration detection (applicable to versions
Off
On
On
Off
On
On
DIP 9: Sway recognition Enable/Disable
DIP 10: Green line
WatchIN Installation Manual
AM Relay
0V
Off
On*
On: PIR or MW
Off: PIR + MW
On: Barrier
Off: Wide angle
On: Red LED only
Off: 3 LEDs
On: Enabled
Off: Disabled
with Vibration sensor installed)
On: Enabled
Off: Disabled
On: Enabled
Off: Disabled
On: MW Off during Disarm (unset)
Off: MW On during Disarm (unset)
Note:
Green line is valid when connecting wire from the panel
output (arm follow) to the detector set/unset input.
LEDs
Off
On**
MIN
MAX
2.40M
3.00M
3.70M
7

Publicidad

Tabla de contenido
loading

Tabla de contenido