8 Motor stroke learning
1. Scroll down the parameters with
2. Access the parameter by pressing the
3. When "
" flashes, continue pressing the
4. Release the
key when "
the power supply, inverse the operator cables and repeat the operation);
5. Wait for the door (or doors in case of using 2 motors) searches and stops on the opening stop and then on the closing stop.
If you want to anticipate the stopping strokes in opening, you can manually intervene by giving an impulse to "Start" button (or
pressing the "OK" on the control panel) simulating the stroke.
Warning: For operators without encoder, the stroke is not detected, so it MUST be simulated both while opening and while closing (for
both oeprators) by pressing the
6. Once the procedure is ended, the display will show "- - - - ".
Type 01 and
WARNING (only
then check the manual release to make sure it is working properly. If it's to "hard" increase the value of P057 of 1 or more.
9 Transmitters learning
9.1 Transmitters coding selection
1. Scroll down the parameters with
P027;
2. Confirm by pressing on the
3. Select the type of transmitter by scrolling
- d000=fix rolling-code (suggested);
- d001=complete rolling-code;
- d002=dip-switch;
4. Confirm by pressing on the
Warning: If you need to vary the type of encoding, and only if other remo-
tes with different encoding are memorized, you need to erase memory
(P004) AFTER you have set the new encoding.
9.2 Learning
1. Scroll down the parameters with
keys until you visualise P005;
2. Confirm by pressing on the
3. When the symbol "
any key of the transmitter you want to memo-
rize;
4. The display visualizes the number of the trans-
mitter just memorized and then "
5. Memorize all necessary transmitters repeat-
ing this procedure from step 3;
6. Wait 10 seconds before quitting the memori-
zation mode, display shows now "- - - - ".
Warning: In the case of rolling code remotes,
the receiver can be put into learning mode by
pressing the hidden button on a remote control
previously learned.
36
and
keys until you visualise P003;
key;
key;
" stops flashing; Start the learning procedure with operator 1 opening (if it starts closing, disconnect
key.
Type 03) Once you have executed the learning stroke, operate a complete cycle (opening/closing) and
and
keys until you visualise
key;
and
keys:
key (display shows again P027).
and
key;
" appears, press on
";