5 ELECTRICAL CONNECTIONS
Execute the wiring following the directions of table 1 and diagrams.
WARNING To ensure an appropriate level of electrical safety always keep the 230V power supply cables apart (minimum 4mm in the
open or 1 mm through insulation) from low voltage cables (motors power supply, controls, electric locks, aerial and auxiliary circuits
power supply), and fasten the latter with appropriate clamps near the terminal boards.
WARNING Connect to the power supply 230 V ~± 10% 50 Hz through a multi pole switch or a different device that can ensure multi pole
disconnection from the power supply, with a contact opening of 3 mm.
WARNING To connect the encoder to the control panel, use only a dedicated cable 3x0,22mm
1-2
230 V ~ ±10% (50/60 Hz) power supply input
3-4-5
Operator 1 output 230 V ~ max 600W
6-7-8
Operator 2 output 230 V ~ max 600W (if present)
9-10
230 V ~ max 150 W output for open gate fix warning light (if P052=0) or courtesy light (if P052>1)
11-12
Flashing light output 230 V ~ max 40W
13 (-)
13-14
14 (+)
15-16
17
Input 6
18 - Com
19
Input 5
20 - Com
21
Input 4
22 - Com
23
Input 3
24 - Com
25
Input 2
26 - Com
27
Input 1
28 - Com
29
Aerial signal input
30
Ground aerial input
31-32
24 V ~ max 200mA power supply output for auxiliary devices
28
Table 1 "terminal board connections"
"Boost" output for electric-lock, max 1 x art. 110 (if P062=0), 24V pulse output, max 5W (if P062=1), step
by step (if P062=2), electro-brake output for not self-locking operators (if P062=3), output for electric-lock
power supply via external relay (if P062=4), output for electro-magnets power supply for barriers (if P062=5)
or temporized output (if P062>5).
Output 24V
max 100mA; by selecting the FL/WL jumper, you can get a clone of the 230 Flash output as
a 24V (if set FL) or as a Warning output (if set WL).
Warning: the output capacity allows to use LED flashing lights only.
TYPE 00
TYPE 01
(FCC 1)
(STOP)
N.C.
N.C.
(FCA 1)
(PHOTO 2)
N.C.
N.C.
( PHOTO 1)
(PHOTO 1)
N.C.
N.C.
(SAFETY)
(SAFETY)
N.C.
N.C.
(PED.)
(PED.)
N.O.
N.O.
(START)
(START)
N.O.
N.O.
TYPE 02
TYPE 03
If unused, short circuit
(NONE)
(NONE)
N.O.
N.O.
(NONE)
(NONE)
N.O.
N.O.
(STOP)
(NONE)
N.C.
N.O.
(SAFETY)
(NONE)
N.C.
N.O.
(PHOTO 1)
(PHOTO 1)
N.C.
N.C.
(START)
(START)
N.O.
N.O.
.
2
TYPE 04
(FCC 1)
N.C.
(FCA 1)
N.C.
(STOP)
N.C.
(NONE)
N.O.
(PHOTO 1)
N.C.
(START)
N.O.