cooking appliance specifies a greater
distance, this must be taken into consideration.
Gas cookers
Comply with the currently valid installation
regulations and instructions of the gas
appliance manufacturers. The extractor hood
may only be installed over gas hobs at a
minimum distance of 750 mm provided the
following nominal thermal loads (Hs) are not
exceeded:
Gas cookers
Load of one hotplate max.
Load of all hotplates max.
Load of the oven
Gas hobs
Load of one hotplate max.
Load of all hotplates
Subject to technical modifications!
Installation Instructions
Module
Image: Hermano
General: The exhaust hood undergoes a
comprehensive function test before it leaves
our factory. In order to improve technical
3.0 kW
8.3 kW
max. 3.9 kW
3.9 kW
max. 11.3 kW
Suspension Point
Electrical Connection
Hose Connection
understanding of the interdependence of the
functional parts, the exhaust hood is delivered
in complete assembled in its final condition.
It must, however, be partially dissembled as
per the following description.
1. Place the hood on its side and press on
the glass pane with both hands until the catch
of the glass pane loosens. Now open the
glass pane from below. Then pull the metal
filter out from below and remove it from the
hood. The metal filter is held in place with
magnets.
2. Now the filter intake with the glass pane
and module (one component) must be
disassembled. To do so, remove the 4 nuts
(M8) from the threaded rod on the top of the
filter intake. Remove the filter intake with glass
pane and module from below.
en