d-dP (choose single or dual display)
3.9.8
When menu displays d-dP, press
to confirm.
3.10. LED LIGHTING
On powering on, long time press
4.
NOTE
1. Not overloading. Not throw heavy things on the scale violently. The damage for overloading is not within the range of guaran-
teed maintenance.
2. Don't use sharp thing to operation the keyboard. if the rubber is damaged it will influence the performance of waterproof.
3. Keep the scale clean in order to weighing well.
4. There is a lead seal on the bottom of the scale. Users are not allowed to remove the seal. If the seal is da- maged the scale is
not guaranteed for maintenance.
5. a. You must charge the battery at least per 3 months when you don't use the scale for long time.
b. Please correctly connect line between adapter and battery, black to black, red to red.
c. If after charging the used time becomes short than often, please change a new battery
5. CALIBRATION
This operation can only be done by competent authorized personnel according to the laws of each country.
• With the scale turned off, unseal the seal of the division modification switch. This switch is located in the inferior face of the
scale.
SS new firmware version 3S-8.1H, no longer calibrated with the usual procedure of holding down the tare key for a few seconds.
Now we must follow the following procedure:
Place the internal switch in the ON position.
Turn on the scale, once we are in weighing mode,
Press
and
The display will show S-Unit , press
The display will show 1P , press
The display will show the maximum capacity of the scale, press
(If necessary, with the SET key can be changed capacity)
The display should now show 0, whether or not, press
Place 1/3 de FS on the pan, wait for stabilization
The display will show the capacity with the flashing digit with the SET key increase the value and the
You must enter the value of the weight that we have loaded on the plate and press
Once there, press
again.
The display will show C0, unload the pan, wait for stabilization and press
The balance will automatically return to weighing mode, the calibration has been made.
→ T ←
to enter, press
, it shows LC-, press
at once and listen for a beep (approx 6s)
NOTE: DURING CALIBRATION, IF YOU WANT TO EXIT, PRESS
to choose "n" or "y", "n" is single display, "y" is dual display. Press
to choose LU-0, LU-1, LU-2, or LU-3. Press
to reach the position of the far right.
to confirm.
USER'S MANUAL SS
→ T ←
to confirm.
key we move to the right.
ON/→ T ←
EN
EN
→ T ←
17