Figure 6: HSM2955(R) terminal connections
RED
BLK
Corbus
YEL
GRN
AUX
AUX
Power
COM
Tamper
TAM
M1
M2
M3
Speaker/Mic
M4
SPK1
Speakers
SPK2
AOUT
GND
Audio
AIN
RNG
TIP
R-1
Phone Line
T-1
Ground
EGND Earth Ground for Telco circuit
2.3 Enrollment
The HSM2955(R) audio verification module can be automatically or manually enrolled at the panel
keypad. See below for enrollment options.
Automatic Enrollment - Enter section [902] and press [000][*] to automatically enroll all new mod-
ules.
Manual Enrollment - To manually enroll the HSM2955(R) enter section [902] then select [001] [*].
When prompted, enter the serial number found on the device. An error tone sounds if an invalid
serial number is entered. The serial number and slot assignment is displayed when the module has
been enrolled successfully.
Confirm Enrollment - To confirm enrollment, enter section [903] then select [108][*].
Delete - Enter [902][108][*] to remove the HSM2955(R) module from the system.
Labels - Enter [000][808] [*] to customize the module label. See the Alarm Panel Installation Manual
for more details.
3. Privacy
The HSM2955(R) module was designed to adhere to applicable privacy regulations and only pro-
cesses data needed for the primary functionality of the device. Before using the module you will
be asked to provide consent with processing of the personal data that the module may capture.
Note that the module records audio to secure the best functionality of the device. The recordings
are processed securely and automatically erased on a periodic basis. Based on the location of the
module you may have the obligation to issue a notice about using it. The data recorded through the
Corbus Power
Corbus Ground
Corbus Com A
Corbus Com B
Auxiliary Power Output (PTC protected locally).
NOTE: Output current is limited by the available current at the panel
AUX/RED
output
Common Ground terminal for station wiring
HSM2955 Module Tamper Input
Microphone #1 (M1) Input Channel
Microphone #2 (M2) Input Channel
Microphone #3 (M3) Input Channel
Microphone #4 (M4) Input Channel
Speaker Level Output (supports two DSC Audio Stations)
Speaker Level Output (supports two DSC Audio Stations)
NOTE: SPK1 and SPK2 are parallel wired from a single audio output. Any
combination of audio stations can be used as long as the maximum current
rating is not exceeded:
- 4 small stations (PC5961E)
- 2 large stations (PC5964E)
- 1 large & 2 small stations
Audio Out
Ground
Audio In
NOTE: This is an alternate terminal block. See Figure 4 for use.
Connected to R-1 terminal on the alarm panel
Connected to T-1 terminal on the alarm panel
Connected to house phones
Connected to house phones
(refer
to
the
Panel
- 6 -
Installation
Manual).