Memory Storage Of Lc Radio Controls (For Some Markets Only); Remote Memory Storage Of Lc Radio Controls; Radio Controls Deletion Procedure; Connection Of Buffer Batteries (Optional) - FAAC E391 Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
9.
Quickly press twice the memory stored radio control push-
button.
The automated system performs one opening
operation. Make sure that the automated
system is free of any obstacle created by
persons or things.
To add other radio controls, transfer the code of the memory-
stored push-button of the radio control to the relevant push-
button of the radio controls to be added, observing the
following procedure.
On the memory stored radio control, simultaneously press
and hold down push-buttons P1 and P2.
The radio control LED begins to flash.
Release both push-buttons.
Press the memory stored push-button and hold it down
(the radio control LED lights up on steady beam).
Bring the radio controls near, press and hold down the
push-button of the radio control to be added, releasing
it only after the double flash of the radio control LED,
which indicates memory storage executed.
Quickly press twice the push-button of the memory stored
radio control.
The automated system performs one opening
operation. Make sure that the automated
system is free of any obstacle created by
persons or things.
8.3 MEMORY STORAGE OF LC RADIO CONTROLS
(for some markets only)
A maximum of 250 codes can be memory
stored, split between OPEN A and OPEN B.
1.
Use LC remote controls only with receiver module at 433
MHz.
2.
Press the LOGIC (SW3) or SPEED (SW2) push-button, to
memory store respectively total opening (OPEN A) or partial
opening (OPEN B), and as you hold it down, also press the
SETUP (SW1) push-button. The relevant LED starts to flash
slowly for 5 sec.
3.
Release both push-buttons. Within these 5 sec., press the
appropriate push-button on the LC remote control.
4.
The LED lights up on steady beam for 1 second, indicating
memory storage executed, and then resumes flashing for
another 5 sec., during which another radio control (point
4) can be memory stored.
5.
When the 5 sec. have elapsed, the LED goes OFF indicating
the end of the procedure.
6.
To add other radio controls, repeat the operation at point 1.
8.3.1 REMOTE MEMORY STORAGE OF LC RADIO CON-
TROLS
Other radio controls can be remotely stored only with the LC
radio controls, i.e. without using the LOGIC-SPEED-SETUP push-
buttons, but using a previously stored radio control.
1.
Get a radio control already stored on one of the 2 channels
(OPEN A or OPEN B ).
2.
Press and hold down push-buttons P1 and P2 simultaneously
until both the LEDs flash slowly for 5 sec.
LOGIC-SPEED-SETUP push-
push-
3.
Within 5 sec. press the push-button of the radio control
that had been memory stored to enable learning on the
selected channel.
4.
The LED on the board relating to the channel being learned
flashes for 5 sec., within which time the code of another
radio control must be transmitted.
5.
The LED lights up on steady beam for 2 seconds, indicating
memory storage executed, and then resumes flashing for
5 sec., during which other radio controls can be memory
stored, and then goes OFF.

8.4 RADIO CONTROLS DELETION PROCEDURE

1.
To delete ALL the input radio control codes, press push-
button LOGIC (SW3) or SPEED (SW2) and, while holding it
down, also press push-button SETUP (SW1) for 10 sec.
2.
The LED relating to the pressed push-button flashes for
the first 5 sec, and then flashes more quickly for the next
5 sec.
3.
Both LEDs light up on steady beam for 2 sec and then go
OFF (deletion completed).
(deletion completed).
deletion completed).
completed). ).
completed).
4.
Release both push-buttons.
This operation is NOT reversible. All codes of
radio controls stored as OPEN A and OPEN B will
be deleted.
9

CONNECTION OF BUFFER BATTERIES (OPTIONAL)

The buffer battery kit will activate the automated system
in the event of a power cut. The batteries are housed in
an appropriate container located inside the operator (see
sequence in fig.4).
To install, consult the specific instructions.
The batteries come into operation when a
power cut occurs.

10 AUTOMATED SYSTEM TEST

When you have finished programming, check if the system is
operating correctly. In particular, check if the safety devices
are operating correctly.
7
3.9 x 16
2
1
Fig. 4

Publicidad

Tabla de contenido
loading

Tabla de contenido