Check Oil Level; Oil Change Procedure; Protecting The Pump; Storing The Engine - Generac 3500PSI Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Generac Portable Products 3500 PSIPressure Washer
Check
Oil
Level
I.
Place pressure washer on a level surface.
2.
While pump and oil is cold, observe oil level visible in
pump's oil sight gauge.
3.
Oil level should be visible and just below red dot. If
necessary, slowly add recommended
oil through
pump's oil filler opening until oil level just touches
bottom
of red dot. DO NOT fill above red dot!
Oil Change
Procedure
I.
2.
3.
4.
5.
6.
7.
8.
9.
Place pressure washer on an outside level surface.
Start and run pressure washer for at least 5 minutes.
Turn off pressure washer and disconnect spark plug
wire from spark plug.
Place suitable container under oil drain hole.
Remove pump's oil filler cap and o-ring (Items 32 and
33 on page 18).
Remove oil drain plug (Items 48 and 49 on page 18)
and let oil drain out completely.
Replace oil drain plug and tighten securely (50 in-lbs
max. torque).
Use a funnel to add recommended
amount and type of
pump oil.
Replace domed oil filler cap and o-ring. Tighten finger-
tight.
I0. Reconnect spark plug wire to spark plug.
I I. Take used oil to an oil recycling center.
PREPARING
THE
UNIT
FOR STORAGE
Water should not remain in the unit for long periods of
time. Sediments or minerals can deposit on pump parts and
"freeze" pump action. If you do not plan to use the pressure
washer for more than 30 days, follow this procedure:
I.
Flush detergent
siphoning tube by placing the filter into
a pail of clean water while running pressure washer in
low pressure mode. Flush for one to two minutes.
2.
Shut off the engine and let it cool, then remove high
pressure and garden hoses. Disconnect spark plug wire
from spark plug.
3.
Empty the pump of liquids by pulling the engine recoil
handle about 6 times. This should remove most of the
liquid in the pump.
4.
Use pump saver to prevent corrosion build up and
freezing of pump.
5.
Store unit in a clean, dry area.
Protecting
the Pump
To protect the pump from damage caused by mineral
deposits or freezing, use PumpSaverto treat pump. This
prevents freeze damage and lubricates pistons and seals.
NOTE: PumpSaver, model number 01559, is availableasan
optional accessory.It is not includedwith the pressurewasher.
CAUTION
• Failure to do so will permanently damageyour pump and
render your unit inoperable.
• Freeze damage is not covered under warranty.
CAUTION
Always wear eye protection when using PumpSaver.
To use PumpSaver, make sure the pressure washer is
turned off and disconnected
from supply water. Read and
follow all instructions
and warnings given on the PumpSaver
container.
NOTE: PumpSaver will drip from pump after treatment
and will stain wood and concrete.
NOTE:
If PumpSaver is not available, draw RV antifreeze
(non-alcohol)
into the pump by pouring the solution
into a
3-foot section of garden hose connected
to inlet adapter
and pulling recoil handle twice.
STORING
THE
ENGINE
See the engine owner's manual for instructions on how to
properly prepare the engine for storage.
I