GE GES-NJGB25IN-1 Manual Del Propietario E Instrucciones De Instalación página 14

Ocultar thumbs Ver también para GES-NJGB25IN-1:
Tabla de contenido

Publicidad

6
Conne ction of wirings and drain pipe
RISK OF ELECTRIC SHOCK OR FIRE. Only suitably quali ed
personnel should make the electrical connec ons.
1. Open the cover A to expose the electrical box.
2. Insert the connecting wiring from the rear of the unit
then pull it out of the front.
3. Loosen the cable clamp and ensure the cable is fed
through the cable strain relief clamp.
4. Loosen the terminal block screws and insert the
connecting wiring ends fully into the terminal block.
Then tighten the screws in the terminal block.
5.Pull the wiring slightly to make sure the wiring has been properly inserted
and tightened.
6. Tighten the cable strain relief clamp.
7. Replace the cover A.
Connecting wiring
8. Install the drain pipe.
Attention:
1. If the supply cord is damaged, it must be replaced by the manufacturer or its
service agent . T he type of connecting wire is H07RN -F.
2. If the fuse on P C board is broken please change it with the type of
T.3.15A/250VA C (Indoor).
3. T he wiring method should be in line with the local wiring standard.
4. A breaker shou ld be incorporated into
all-pole switch and the distance between its two contacts should be not less
than 3mm.
7
F ixing the indoor unit body
1. Wrap the pipes, con necting wirings and drain pipe as follows.
heat insulation materials closely and fi x with adhes ive tape.
F ix with adhes ive tape
cover A
Indoo r unit
To Outdoor unit
2
4G 1.0 mm
xed wiring. T he breaker should be
Cover them with
Indoor/outdoor connne cting wiring
P iping
He at insulation materials
Drain hose
them through the wall hole to the outdoor .
2. Make
3. Hang surely the unit body onto the upper
notches of the mounting plate. Move the body
from side to side to verify its se cure fixing.
4. In order to fix the body onto the mounting
plate,hold up the body aslant from the
underside and then put it down perpen dicularly.
Attention:
. 1.Keep the drain pipe in the warm area to prevent condensation. Problems
with the piping may lead to water leaks and interior property damage.
2.Do not install the drain pipe as follows.
It is raised after exiting the wall.
The end is immersed in water.
It has raised sections near the ground.
Too close to the ground.
The end of the hose is near to drains with bad odours.
3. Pour water in the drain pan of the indoor unit to confirm the
drainage is carried out to the outside of the building without problems.
8
Che ck installation and test run
Refer to the other instructions to install the outdoor unit. Check and
ensure the indoor and outoor units are securely installed. Then put
the power on to test run.
P l e a s e k i n d l y e x p l a i n t o o u r c u s t o m e r s h o w t o
oper ate throug h t h e i n s t r u c t
Are there any gas leaks from the connecting pipes or connections ?
Has ins ulation been wrapped around the connecting pipes?
Are the connecting cables properly ins erted in the terminal blocks and fully tightened?
Is the drainage working properly?
Is the indoor unit securely fixed to the wall?
Is power source voltage the same as the rated voltage of the product?
Is there any unusual noise coming from the indoor or outdoor units ?
Are the lights/dis plays working properly?
Are cooling and heating ( when in heat pump) working properly?
Is the temperature control working properly?
Does the remote control work properly?
Attention:
After the installation of the indoor and outdoor unit, put the
power on to tes t. Th e referen ce indoo r fault code s are as
follows.
C ode
T rouble description
indication
Room temperature
E 1
sensor failure
P i p ing
temperature
E 2
sensor failure
Indoor E E P R O M
E 4
error
C ommunication
fault between
E 7
indoor and outdoor
units
Indoor fan motor
E 14
malfunction
13
mounting plate
o n manua l .
i
Analyze and diagnose
F aulty connector conne ction;
F aulty thermistor;
F aulty P C B;
F aulty E E P R O M data;
F aulty E E P R O M;
F aulty P C B;
Indoor unit- outdoor unit signal
transmission error due to wiring
error;
F aulty P C B;
O peration halt due to fan
m o t o r f a ul t;
Detection error due to faulty
indoor unit P C B;

Publicidad

Tabla de contenido
loading

Tabla de contenido