General Information; Wall Mounting - DeLonghi HOLMO DRY ELETTRICO Manual De Instrucciones Para El Uso

Radiador eléctrico
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
1. SPEcIFIcaTIONS OF ThE aPPLIaNcE
Voltage: 230 V ~ 50 Hz
Insulation class: II
Protection class: IP24
Power [W] Length [cm]
700
52
1000
60
1500
84
2000
108
Table 1
The technical specifications of the appliance are
indicated on the rating plate on the side of the ra-
diator (Fig. 1).
A Brand/Manufacturer
B Model, type, category
EN
C Bidimensional Code (QR)
D Protection class
E CE marking

2. GENERaL INFORmaTION

Unpack the appliance carefully and rest it on the
polystyrene corner pieces or a carpet.
The package contains:
– the appliance
– remote control (if provided) with two batteries and
container for wall mouting
– mounting kit
– instructions
Read all the instructions carefully before installation
and use. Keep for future consultation.
Install and use the appliance as described in these
instructions only.
These instructions do not cover all situations which might
arise. Caution and common sense should be applied
when installing, operating and servicing the appliance.
Modifying the characteristics of the appliance and
removing any fixed component including the caps
is expressly prohibited.
Make sure the appliance is complete and undam-
aged. If damaged, do not use the appliance, but
contact your local dealer or a qualified professional.
The materials used for packaging can be recycled. You
are therefore recommended to dispose of them in
special differentiated waste collection containers.
Height
Weight
Rated current
[cm]
[kg]
[A]
58
15
3
58
18
4,5
58
25
6,5
58
33
9
F Double isolation
G Disposal procedures
H Quality marks
I
Voltage and Power
L Serial number
3. POSITIONING aND INSTaLLING
The appliance is designed to heat domestic rooms
or similar. It must not be used for other purposes.
The appliance must be used permanently mounted
on a wall as described in the instructions.
Install the appliance with the control panel at the
top (Fig.2).
In bathrooms (with bath or shower), install the ap-
pliance outside zone 1 (Fig. 2).
The appliance must be installed in such a way that
the electronic controls and other control devices
may not be touched by someone in the bath or
shower (Fig. 2). The electronic controls and other
control devices must always be in zone 3. The ap-
pliance must not be connected with a plug.
For radiators with power plugs, see the
warnings on page 56.
Respect the distances shown in figures 3,4.
Never install the appliance:
– immediately below or in front of a power socket or
a junction box (Fig. 5)
– in contact with the wall or floor
– near curtains, flammable or combustible materials
or pressure vessels.
Make sure there are no pipes or electric wires in the
wall which could be damaged while mounting the
appliance.
The appliance is equipped with a sensor which
can detect an Open Window, if present above the
radiator or within the room. For a proper opera-
tion, it is strongly recommended to comply to the
installation directions reported in Ch. 4.3.1 before

wall mounting.

3.1 WaLL mOuNTING
Make sure the screws and anchors included in the
mounting pack are suitable for the type of wall
on which you are mounting the appliance. If in
doubt, contact a qualified professional or your lo-
cal dealer.
The installation template is on the back of the box.
Open up the box completely and rest it against the
wall. Follow the installation sequence shown on
the folding leaf of the cover (Scheme 1), respecting
the minimum distance between the bottom of the
radiator and the floor (Fig. 3).
44

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Kendra elettricoLaguna elettrico

Tabla de contenido