CHARGING THE BATTERY
Charge the battery each time the machine is used, or whenever the Battery Condition Meter Lights (DD) are fl ashing.
To Charge the Battery...
1
Open the Battery Compartment Door (21) to provide proper ventilation.
2
Disconnect the battery from the machine (KK) and connect the charger plug to the battery plug.
3
Follow the instructions on the battery charger.
4
Check the fl uid level in all battery cells after charging the battery. Add distilled water, if necessary, to bring the fl uid level up to the bottom
of the fi ller tubes.
WARNING!
Do not fi ll the battery before charging.
Only charge battery in a well-ventilated area.
Do not smoke while servicing the battery.
CAUTION!
To avoid damage to fl oor surfaces, always wipe water and acid from the top of the battery after charging.
CHECKING THE BATTERY ELECTROLYTE LEVEL
Check the electrolyte level of the battery at least once a week.
After charging the battery, remove the vent caps and check the electrolyte level in each battery cell. Use distilled water to fi ll the battery to the
bottom of the fi ller tube.
Do not over-fi ll the battery!
CAUTION!
Acid can spill onto the fl oor if the battery are overfi lled.
Tighten the vent caps. If there is acid on the battery, wash the tops of the battery with a solution of baking soda and water (2
tablespoons of baking soda to 1 quart of water).
FORM NO. 56041577 - Captor
ENGLISH / A-21
4300B, 4800B / CR 1100B, 1200B - A-21
™