Troubleshooting (continued)
Symptom
1. No Power
2. Switch failure
Motor inoperative
3. Motor failure
4. Thermal protector failure
5. Incorrect/loose wiring
1. Bad o-ring gasket
2. Dirty shaft seal
Fluid leakage
3. Bad shaft seal
4. Incompatible fluid
5. Loose fasteners
1. Dirt in pump cavity
Pump hums but
2. Motor failure
will not operate
3. Broken rotor insert
Bold text indicates repairs that are not serviceable by the owner; please refer to our warranty policy on page 2 for further instructions.
* Repairs marked with an asterisk (*) will require Repair Kit #300KTF7794. This kit includes a replacement rotor and new vanes, as well as a number of other important seals and
components to complete the repair.
Accessories
A wide variety of accessories are available to help you maximize the performance of your Fill-Rite pump. Listed below are the applicable available accessories for your specific product.
Please contact your authorized Fill-Rite distributor to purchase the accessories you need.
Part Number
Description
F4010PM0
1" Filter (Particulate 10 micron)
F4030PM0
1" Filter (Particulate 30 micron)
700ACCF7017
1" Filter Head
FRPA125
Island Pedestal Mount Kit
KIT700AS
Anti-Siphon Kit
FRH10012
1" Hose (12')
FRH10014
1" Hose (14')
FRH10020
1" Hose (20')
Cause
Check incoming power.
Refer to warranty policy.
Refer to warranty policy.
Refer to warranty policy.
Check wiring.
Check all o-ring gaskets.
Clean seal and seal cavity.
Replace seal.
Refer wetted parts list to fluid manufacturer (see page 7).
Tighten fasteners.
Clean out pump cavity.
Refer to warranty policy.
Remove all debris & replace insert.
INSTALLATION AND OPERATION MANUAL
Solution
Part Number
Description
FRHA10020
1" Arctic Duty Hose (20')
FRHMN100S
1" Nozzle, Manual Leaded Spout
N100DAU13G
1" Auto Shut Off Nozzle (Ultra High Flow Diesel)
N100DAU12G
1" Auto Shut Off Nozzle (High Flow Diesel)
FRNA100DAU00
1" Auto Shut Off Nozzle (Arctic Duty - Diesel)
S100H1315
1" Multi-Plane Swivel
B100F475
1" Breakaway
WH10012
1" Whip Hose
fillrite.com | tuthill.com
9