1. General information
The filter system consists of the following parts (see page 3):
• Everpure Claris Head Gen2 with mounting bracket and bypass setting key
• Filter cartridge
The filter cartridges are available in different varieties and sizes:
- Everpure Claris: S, M, L, XL, XXL
- Everpure Claris ULTRA: 170, 250, 500, 1000, 1500, 2000
- Everpure Claris PRIME
The corresponding Generation II head fits to all Everpure Claris cartridges and sizes.
2. Operating and safety instructions
2.1
Staff
The installation and maintenance of the filter systems may only be carried out by trained and authorised personnel.
2.2
Disclaimer
Information contained in this document is believed to be accurate at the time of publication, but does not constitute a
contractual offer. The right is reserved to alter specifications without prior notice. Illustrations and tabulated data are for
guidance only. Pentair does not assume liability for any damages, including subsequent damages, that may result from
incorrect installation or usage of the products. Pentair does not assume liability for damage caused by using parts from
other manufacturers.
2.3
General safety instructions
• Only cold water of potable water quality may be used to feed the system.
• All components must be stored dry within a temperature limit of -15° to 45° C (5 °F to 113 °F)
• The system must be sited in a frost-proof place and be protected from direct sunlight.
• The system must not come into contact with chemicals, solvents or other vapours.
• Before commissioning the filter system, the fed appliance must be free of lime.
• The filter cartridge must not be opened or damaged.
• Regardless of the residual capacity, the filter cartridge must be replaced if not used for more than 4 weeks and if not
flushed periodically with efficient volume (see table for flush volume).
• Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before
or after the system.
• After 5 years of use (latest 6 years after production date) the filter head and wall mounting bracket must be
replaced (this also applies to hoses and gaskets) – please check the date on the production stamp.
• After a longer downtime or maintenance works rinse the system thoroughly – see table for flush volume.
Filter system
Claris S / ULTRA 170 / ULTRA 250
Claris M / ULTRA 500
Claris L / ULTRA 1000
Claris XL / ULTRA 1500
Claris XXL / ULTRA 2000 / Claris PRIME
2.4
Assembly safety instructions
•
Water pressure at the filter system inlet must not exceed 8 bar (116 psi). A pressure reducer must be installed on the
water supply side of the filter system if the inlet pressure exceeds 8 bar (116 psi).
•
A shut-off valve must be installed upstream of the filter system.
•
If a water softener is installed upstream, check if hardness is still available in the tapwater.
•
No copper pipes, galvanised or nickel-coated pipes or intermediate parts may be installed between the filter system
and the point of dispense.
•
All components must be installed according to country-specific guidelines. Check for compliance with state and local
laws and regulations.
•
DIN 1988 should be noted for installing and operating the system.
•
We recommend only using genuine accessory hoses for the Easy Head with 3/8" BSP connection because these
have a longer thread
•
If the cartridge is removed from the filter head without being replaced by a new one, the water supply to the filter
head must be shut off.
•
Do not connect any devices to the flush valve and/or flush hose.
•
Notice for espresso coffee and vending machines: If copper or nickel coated copper parts are used in installations
their surfaces can migrate copper ions if in contact with water. Limestone coating deposits on contacting parts, such
as pipes or boilers, can also impact the level of migration. To avoid the migration of copper ions in the water we
recommend you avoid the use of copper or other nickel-coated copper materials. For installations which still consist
mainly of copper, brass or nickel-coated copper surfaces, we recommend to use only the Claris ULTRA filter
cartridge family or Claris PRIME.
Flush volume
after 1 week of stagnation
2 liters (0.5 US gal)
3 liters (1.0 US gal)
5 liters (1.5 US gal)
8 liters (2.0 US gal)
12 liters (3.0 US gal)
15
Flush volume
after 4 weeks of stagnation
10 liters (3 US gal)
15 liters (4 US gal)
25 liters (7 US gal)
40 liters (11 US gal)