Section 2: General Information
Specifications

Generator

Model
Rated Voltage
Rated Maximum Load
Current (Amps) at Rated
Voltage*
Main Circuit Breaker
Phase
Rated AC Frequency
Battery Requirement
Enclosure
Weight (lbs/kilos)
Normal Operating Range
These generators are rated in accordance with UL 2200, Safety Standard for Stationary Engine Generator Assemblies, and CSA-C22.2 No. 100-04
Standard for Motors and Generators.
* Natural Gas ratings will depend on specific fuel joules/Btu content. Typical derates are between 10-20% off the LP gas rating.
** Circuits to be moved must be protected by same size breaker. For example, a 15 amp circuit in the main panel must be a 15 amp circuit in the
transfer switch.
Engine
Model
Type of Engine
Number of Cylinders
Displacement
Cylinder Block
Recommended Spark Plug
Spark Plug Gap
Valve Clearance
Starter
Oil Capacity Including Filter
Recommended Oil Filter
Recommended Air Filter
Engine power is subject to and limited by such factors as fuel Btu/joules, ambient temperature and altitude. Engine power decreases about 3.5 percent
for each 1000 feet (304.8 meters) above sea level, and also will decrease about 1 percent for each 6 ºC (10 ºF) above 15 ºC (60 ºF) ambient temperature.
The specification sheet for your generator was included in the documentation provided with the unit at the time of
purchase. For additional copies, consult your local Independent Authorized Service Dealer for your specific generator
model.
6
8 kW
11 kW
33.3
35 Amp
50 Amp
Group 26R, 12 Volts and 540 CCA Minimum
Aluminum
Aluminum/Steel
394/178.7 (Steel)
378/171.5
358/162.4 (Aluminum)
This unit is tested in accordance to UL 2200 standards with an operating temperature of -20 ºF (-29 ºC) to 122 ºF
(50 ºC). For areas where temperatures fall below 32 ºF (0 ºC) a cold weather kit is recommended. When operated
above 77 ºF (25 ºC) there may be a decrease in engine power. (Please reference the engine specifications section.
8 kW
GH-410
1
410 cc
0.508 mm (0.020 in)
0.05 - 0.1 mm
(0.002 - 0.004 in)
Approx. 1.5 qt/ 1.4 l
16 kW
240
45.8
66.6
65 Amp
1
60 Hz
Aluminum/Steel
455/206.4 (Steel)
419/190 (Aluminum)
11 kW
GTH-530
2
530 cc
Aluminum w/ cast iron sleeve
see
Replacement Parts
0.76 mm (0.030 in)
1.02 mm (0.040 in)
0.05 - 0.1 mm
(0.002 - 0.004 in)
(0.002 - 0.004 in)
12 VDC
Approx. 1.7 qt/ 1.6 l
Approx. 1.9 qt/ 1.8 l
see
Replacement Parts
see
Replacement Parts
Owner's Manual for 60 Hz Air-cooled Generators
20 kW
83.3
90 Amp
(see
Replacement
Parts)
Steel
505/229
16 kW
20/22 kW
GT-990
2
992 cc
1.02 mm (0.040 in)
0.05 - 0.1 mm
0.05 - 0.1 mm
(0.002 - 0.004 in)
Approx. 1.9 qt/ 1.8 l
22 kW
91.7
100 Amp
Aluminum
476/216
GT-999
2
999 cc

Publicidad