The documentation can be downloaded in PDF version from
EN
the link: www.telwin.com/usermanual
be sprayed or come into contact with the acid, rinse
water. Continue to rinse the area until the physician
DO NOT SMOKE.
- Position the batteries to be charged in a well-
when using acid lead accumulators.
clothing or jewellery that can get caught up in
insulated protection clothing and non-slip boots
must be worn at all times. Persons with long hair
must tie it back and wear a hair net.
- Inexperience and untrained people should be
properly instructed before using the appliance.
- People (children included) whose physical, sensory
person who is responsible for their safety while the
appliance is in use.
not play with the appliance.
- Use the battery charger only indoors and make sure
that you start it in airy places. DO NOT SET IN THE
- Disconnect the mains cable before connecting to or
disconnecting the charging cables from the battery.
- Do not connect or disconnect the clamps to or from
the battery with the battery charger operating.
bonnet.
- Substitute the mains cable only with an original one.
- Do not use the battery charger to charge batteries
which are not rechargeable.
corresponds to that shown on the battery charger
rating plate.
- This battery charger has components such as
switches and relays which can cause arcs or sparks.
Therefore when using it in a garage or in a similar
place set the battery charger in a suitable case.
- Repair or maintenance of the inside of the battery
charger can be executed only by skilled technicians.
- The battery charger is protected from indirect
contact by an earth wire as indicated for class I
equipment. Make sure the power outlet is protected
by an earth connection.
- In models without this element, connect plugs
indicated on the rating plate.
This battery charger complies with the requirements
of the technical standard for products to be used
purposes. No compliance with the electromagnetic
compatibility in domestic use buildings is guaranteed
supply network that furnishes buildings designated to
domestic use.
2. GENERAL DESCRIPTION
Battery charger indicated for charging WET, GEL, AGM,
PbCa lead batteries used by motorised vehicles (petrol and
diesel) and electric vehicles: automobiles, motor vehicles,
motorcycles, boats, etc. It is possible to charge 6V, 12V and
24V batteries; the 50 model also has a starter aid mode (for
vehicles with petrol and diesel engines only).
3. INSTALLATION
When running, position the battery charger in a stable
which guarantee required ventilation is not blocked.
3.2 CONNECTION TO THE MAINS
- The battery charger must only be connected to a power
supply system with neutral conductor connected to
earth.
- Check that the mains voltage is the same as the battery
charger voltage indicated on the rating plate.
- The power line must have a protection system, such as
fuses or circuit breakers, that can support the maximum
apparatus absorption.
- Use the relative power cable when connecting to the
mains.
- Any power cable extensions must be of suitable section
size, never lower than that of the supplied power cable.
- It is always compulsory to connect the device to the
grounding system, using the yellow-green wire in the
two wires must be connected to the phase and neutral
conductors on the mains power supply.
4. OPERATING DURING CHARGING
of the battery to be charged is not lower than that
indicated on the battery charger rating plate (Cmin).
below.
If the battery to be charged is the WET type, the procedure
is as follows:
- Remove the battery caps (if present), so that the gas
produced during charging can exit. Make sure the level
of electrolyte covers the battery plates; if they are not
covered, add distilled water until they are submerged by
5-10 mm.
CORROSIVE ACID.
- Check that the power cable plug has been disconnected
from the mains socket.
- Connect the red charging clamp to the positive battery
- 5 -