4. ASSEMBLY:
After installation of the housing and the clamp, if it Is a prefabricated swimming pool, assemble the floodlamp.
To connect the floodlamp to the electric power supply Insert the cable through the gland seal nut (25). Tíghten the gland seal nut
until you can verify that the cable wlil not yleid when you pulí on it wlth your hand.
Take the precautlon of leaving 1.5 m of cable wound on the floodlamp houusing(Nº 18) in order to be able to remove the floodlamp
to the edge of the pool in the event that lamp replacement or handiing is required. (Fig. 5).
Insert the entire floodlamp assembly in the housing (Fig 6). In order to ofatain good pool lighting it ¡s important that the anagram of
the decorative ring (Nº 1) is located on the upper part (Fig 7).
Screw in the two M-6 x 80 screws (Nº 2) until the fastening dog is secured in the inner walls of the housing (Fig. 8)
5. MAINTENANCE:
This projector does not require any type of maintenance. If the projector does not work properly, please contact our customer
attention department.
It is forbidden to handle the inside of the projector. All projectors which have been handled will lose their guarantee.
If you wish to remove the projector from the swimming pool, it must be done by suitably qualified technician.
To remove the floodlamp to the edge of the swimming pool (Fig. 5) loosen the two DIN 966 M-6 x 80 screws (Nº 2) untll the
fastening dog ylelds sufficlentiy so that the floodlamp unlí can be separated from the housing.
Attention:
Before any handiing ensure that there is NO voltage supplied to the floodlamp.
6. CONNECTION:
In both cases, you should make sure that the voltage received by the lamp is never more than 12V. The transformer must be able to
supply 60VA for each led spotlight connected. For example, if you want to control 6 spotlights, you must connect them in parallel to
a transformer of at least 300VA.
The projector should only be operated underwater and anchored to the vertical walls of the pool. The spotlight is supplied with heat
protection, which in the event of excess temperature reduces the lighting level to avoid overheating.

7. SAFETY WARNINGS:

The persons who are In charge of assembly shouid have the required qualificatlons for this type of work.
Avoid making contact with the electric voltage.
Comply with the currení standards regarding accident preventlon.
In this regard, the IEC 364-7-702 standards must be observed. WIRING IN BUILDINGS. SPECIAL WIRING. SWIMMINGPOOLS.
Any operation related to the maintenance or replacemení of parts shouid be performed with the floodlamp disconnected from the
electric power system.
Do not handie wlth wet feet.

Publicidad