Safety Warnings - Astralpool 37167 Manual De Instalación Y Mantenimiento

Proyector subacuático con par56 de leds monocolor
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6
6. CHANGE OF LAMP:
To remove the floodlamp to the edge of the swimming pool (Fig. 1) loosen the two screws (no. 2) until the fastening dog yields sufficiently so
that the floodlamp unit can be separated from the housing. (Fig. 6 and 7)
To remove the lamp, unscrew the 6 nuts (no. 9) which secure the decorative ring (no. 1) to the base of the floodlamp (no. 7) (Fig. 8).
Remove the lamp (no. 5) from the inside of the base of the floodlamp (Fig. 9) and disconnect the two terminals, loosening the two screws which
secure them to the lamp (Fig. 10).
Change the lamp and assemble the Floodlamp, in the opposite order described in point 4 of assembly, taking special care to:
Connect the cable terminals to the lamp, using the 2 screws supplied with the lamp (Fig. 10).
Fully centre the 110x11 O-ring (no. 6) in its seat.
Firmly tighten the nuts.
Attention:
Before any handling ensure that there is NO voltage supplied to the floodlamp.
The new lamp should have the same characteristics as that supplied with the floodlamp, of led PAR56, 12 V.
In order to ensure full watertightness, clean the seat of the O-ring (no. 6) for the lamp or replace the O-ring if you observe any notches or
permanent damage.
THE HOLES AT THE BACK OF THE LAMP (FIG. 11) SHOULD BE LEFT FREE WHEN ASSEMBLING THE PROJECTOR, SO THAT WATER
7. START-UP:
The components listed below are optional.
Rustproof clamp, code 00362R0001: This housing replaces housing the n. 21 shown on page 14.
Cable duct hose, code 28138:
cable for installation. Protects the electric cable from blows and grazing.

8. SAFETY WARNINGS:

The persons who are in charge of assembly should have the required qualifications for this type of work.
If the end cable of this light fitting is damaged, it should only be replaced by the manufacturer, its technical service or by a similarly qualified
person, to avoid any danger.
Avoid making contact with the electric voltage.
Comply with the current standards regarding accident prevention.
In this regard, the IEC 364-7-702 standards must be observed. WIRING IN BUILDINGS. SPECIAL WIRING. SWIMMING POOLS.
Any operation related to the maintenance or replacement of parts should be performed with the floodlamp disconnected from the electric
power system.
Do not handle with wet feet.
The lamp is designed TO BE USED ONLY SUBMERGED IN WATER and TO OPERATE ONLY WITH A SAFETY TRANSFORMER.
The manufacturer is not responsible in any circumstances for assembly, installation or start-up of any electric components which have been
inserted or handled at locations other than its own premises.
The projector is equipped with a 2x1.5 section cable according to the power of the lamp supplied. If the lamp is changed, the cable section
should be recalculated and changed if necessary.
A T T E N T I O N
CAN FLOW INSIDE FOR OPTIMUM PERFORMANCE OF THE LAMP.
This hose fits in with the gland seal body, and thus ensures waterlightness. Facilitates maintenance of electric
3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

3716837169371703717137172

Tabla de contenido