Descargar Imprimir esta página

Setup - Calibration Flow Rate Spm - Aqua HC151 PH-RX Manual De Programación

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 79
HC151 PHRX
Digital multifunction solenoid metering pump
4.1.2 SETUP – CALIBRATION FLOW RATE SPM
This menu allows you to calibrate the pump. Calibration can be performed if the priming was
performed. The menu consists:
Automatic
FLOW RATE
Manuale
<P> l/h
ADSP9500092
CALIBRATION
FLOW SPM
CALIBRAT. TYPE
MANUAL/AUTOMATIC
Use the Up and Down
key to set flow rate
ENTER
Press and hold the ESC key to return to the previous menu.
14/04/2015 Rev. 1.0
ENTER
Use the Up and Down keys to
choose the calibration this has to be
done automatically or manually.
Press the Enter key to confirm the
choice.
STROKES NUMBER
.
<N> (E)
ENTER
L1 : <nL1> ml
ENTER
START
<N> BATT. (E) (countdown)
At the end of strokes
L2 : <nL2> ml
ENTER
FLOW RATE
<P> ml
<N> is the number of strokes
the pump will perform. You can
set it by the Up & Down keys
Range: 0...1000
<nL1> is the initial quantity of
product. You can set the value
by the Up and Down keys.
Press and hold the Enter
key to start calibration
<nL2> is the quantity of product
left. You can set the value by the
Up and Down keys.
<P> is READ ONLY calculated
value
ENGLISH
36/123

Publicidad

loading