Astralpool PoolWatch Basic Eco Manual De Instrucciones página 23

Ph/ppm cl no estabilizado célula galvánica autolimpiable
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4. INORGANIC CHLORINE ECO INSTALMENT
The PoolWatch Basic Inorganic Chlorine Galvanic is presented in a PVC panel (60 cm x 60 cm)
1.- Fix the panel to the wall with the separators provided.
2.- Connect the set to a 230 V ac with a direct earth connection (they do not have to depend on a filter working).
3.- Put the pH probe (8) in the location area before of the analysis chamber chlorine sensor (A). Take the pH probe and remove the
plastic protections in both extremes, then screw it in the location zone (see page 4).
4.- Connection of pH probe. Take the wire connection (7) and connect it to the pH electrode through the extreme ended in a thread. Its
connections correspond to the positions 23 and 24 in the grid.
5.- It is advisable to sep all the protections and lids for a possible future use (for instance, during a long stop, due to reparisons, etc).
6.- The cell of Inorganic Chlorine (15) is in the of the analysis chamber (13). The connections of the Inorganic Chlorine cell to the grid
are the following;
Black 25 (negative), Red 26 (positive)
7.- The water connection that feeds the water admisión to the PoolWatch Basic Inorganic Chlorine Galvanic must be as similar as
possible to the swimming pool water. This is why we recommend making an instalment according to what is shown in the graph
enclosed. We also recommend filtering part of the water through the bottom of the pool.
NOTE: In case the swimmimg pool has not been built ywt, ask the department of customer Assistance in ASTRAL POOL.
ATTENTION: It is important that the feeding in PoolWatch Basic Inorganic Chlorine Galvanic has a good earth connection, as a security
and also to guarantee its proper functioning. Otherwise, it could provoke instability in the parameters reading. Taking this into account,
we advise to give the PoolWatch Basic Inorganic Chlorine Galvanic a proper earth connection.
5. INSTALLATION DIAGRAM FOR INORGANIC CHLORINE (SODIUM HIPOCLORITE)
Net water
Compensation tank
NOT TO PLACE THE TANKS OF CHEMICAL PRODUCT UNDER THE DOSING PUMPS.
THE CHEMICAL PRODUCTS MUST BE FAR FROM THE DOSING PUMPS AND OF THE EQUIPMENT POOLWATCH BASIC ECO.
Non stop flocculation unit
Pump recirculation
PE Pipe 8 x10 mm
PE Pipe 8 x10 mm
6
SWIMMINGPOOL
Filter
Exchange temperature
Mín 20 cm
Ref: PW Basic-Eco-28472-gb-W01
I n jec t ion P E pipe s
4 x 6 m m
Tank
Tank pH
sodium
corrector
hypoclorite
Safety
Safety
basin
basin

Publicidad

Tabla de contenido
loading

Tabla de contenido