Astralpool PoolWatch Basic Eco Manual De Instrucciones página 28

Ph/ppm cl no estabilizado célula galvánica autolimpiable
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

10.1 GRID CONNEXTORS GRAPH
c
ALI.
230 Vca
REL
T ag strip wic h has
to be plac ed in
eac h terminal
10.2 GRID CONNECTORS
1, 2, 3 Input 230 V ac 50/60 Hz + earth connection.
1
4
Bridge to feed the power circuit (it is already included in the manufacturing)
2
5
Bridge to feed the power circuit (it is already included in the manufacturing)
6 7
Output 230 V ac for the pH dispenser pump. Relay 2
8 9
Output 230 V ac for the Chlorine dispenser pump. Relay 1
10 (-), 11(E) and 12(+) Connection to the flow detector. Inductive pickup.
13 (GND),14 (TX),15 (GND),16 (RX) Connectors to communicators.
17,18
Output mA pH (optional)
19, 20
Output mA Cl (optional)
21 22
Output connection PT-100, sensor Tª (Optional)
23 24
pH electrode connection (23 heald – blue 24 active - translucent)
25 26
Connection to the chlorine cell (25 negative black, 26 positive red).
27
Equipotential.
Important note: The small plate on the last part of the grid is a protection of the electrostatics sign: DO NOT REMOVE. If it is lost, it can
cause jamming in the pH and Cl readings.
10
11
E
REL2
REL1
FLOW
11
12
GND
RX
GND
TX
COMM.
OUT PUT S
Whithout lids
or strips
Metalic sc reen
Ref: PW Basic-Eco-28472-gb-W01
INPUT S
INPUT S

Publicidad

Tabla de contenido
loading

Tabla de contenido