12. GUARANTEE
All the PoolWatch Basic Eco pH / Inorganic Chlorine, equipment range has a guarantee on material and manufacturing failures for a
year. This guarantee does not include the misuse on the customer's side.
This guarantee does not include in any case the substitution of the detrition elements such as the electrodes.
13. PROBLEMS AND SOLUTIONS CONTROL 3 pH /CHLORINE INORGANICÁNICO
PROBLEMS
pH level above the programmed
value (if enhancer is used)
pH level below the programmed
value (if reducer is used)
Chlorine level over the programmed
value.
Chlorine level below the
programmed value.
Led indicator of the pH or Cl pump
dispenser connector (activated) but
the pump dispenser is not working.
The engineered valve does not open
and the relay is on.
The physicochemical analysis of the
pool water, that is the pH and Cl
level do not correspond to the
PoolWatch Basic Eco pH / Inorganic
Chlorine reading. (There is too much
difference)
The pH and/or ppm reading in the
LCD flashes
The flow alarm is on.
CAUSES
You selected a % of the dispenser pump
higher than the suitable one.
You selected a % of the dispenser pump
higher than the suitable one.
The chlorine dispenser pump has a higher
percentage than the suitable one.
The chlorine dispenser pump has a lower
percentage than the suitable one.
a) The connection bridge of the connectors
1-4 and 2-5 of the grid connectors has not
been done.
b) Filtering stopped
c) Delay activated
Improper connection
a) Dirty cartridge filter (see pages 5-6 point
n 5)
b) Dirty electrodes
c) Expired electrodes.
d) Unproper photometer reading.
e) High water
temperature > 28ºC
Imbalance of pH and / or ppm electrode
a)
There is no water running through the
analysis chamber
b)
Faulty connection to the flow detector
13
SOLUTIONS
Reduce the % adjusting it to the pool
characteristics.
Reduce the % adjusting it to the pool
characteristics.
Reduce the percentage adjusting it to the pool
characteristics.
Increase the percentage adjusting it to the pool
characteristics.
a) Do the connection to the connectors 1-4 and 2-
5 of the grid connector.
b) If the filtering is in automatic mode, wait until it
starts working according to the selected time, or
switch the filtering on manually.
c) Switch off the delay pressing the button 2d.
Review power connection (see diagram page 11).
a) Clean.
b) Clean with cleaning solution.
c) Change them.
d) Calibrate photometer
e) Insert the compensating value of water
temperature in the equipment through the
programming.
Calibrate again
a) Check the hydraulic circuit circulation of
PoolWatch Basic Eco pH / Inorganic Chlorine
b) Verify and do the right connection to the flow
detector.
Ref: PW Basic-Eco-28472-gb-W01