GYS PROTIG 201 AC/DC Manual De Instrucciones página 20

Ocultar thumbs Ver también para PROTIG 201 AC/DC:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
Translation of the original instructions
201
039704
ACTIVATION OF THE VRD FUNCTION (VOLTAGE REDUCTION DEVICE)
This device protects the welder. The welding current is delivered only when the electrode is in contact with the part (low resistance). As soon as the
electrode is removed, the VRD function lowers the voltage to a very low value.
The VRD function is originally disabled. However, this can be activated by means of an ON/OFF switch on the power source control board. To access
it, follow the steps below:
1. DISCONNECT THE PRODUCT FROM THE POWER SUPPLY BEFORE HANDLING.
2. Remove the screws to take the power source cover off.
3. Locate the switch on the control board (red box on diagram below - n° 2).
4. Turn the switch located on this control card ON. The red LED switches off.
5. The VRD function is activated.
6. Screw the power source cover back on.
7. On the interface (HMI), the LED for the VRD function is lighted :
To deactivate the VRD function, simply turn the switch located on the control board back to OFF. The VRD LED on the HMI is turned off.
RESETTING THE WELDING STATION
It is possible to restore the factory settings of the welding machine. When the station is in sleep mode, press the sleep exit push button for 3 seconds.
The station then displays "3", "2", "1" and then resets the unit.
DISPLAY OF SOFTWARE VERSIONS
When the machine is plugged into the mains, it displays the software versions of the power and the HMI boards.
20
PROTIG 201 AC/DC - 201L AC/DC
201L
201
041257
038271
2
201L
045675
038202
EN
045682
1

Publicidad