Idiomas disponibles

Device elements

1 Electrodes
2 Handle
3 Suction hose
4 Power cord
5 Suction head lock
6 Wheel
7 Dirt receptacle
8 Suction head
9 Steering roller bow
10 Steering roller
11 Floor nozzle
12 Suction tube
13 Suction support
14 Main switch
15 Carrying handle
16 Filter cover
17 Push handle
18 Nameplate
19 Bender
20 Slide for filter cleaning
21 Floor nozzle holder
22 Drain hose
23 Exhaust filter
24 Flat fold filter

Start up

Caution
The flat pleated filter must always be in
place while vacuuming.

Dry vacuum cleaning

When vacuuming fine dust, you may
also use an additional paper filter bag or
a membrane filter (special accessory).
Inserting the paper filter bag
Illustration
 Release and remove the suction head.
 Insert the paper filter bag or the mem-
brane filter (special attachment).
 Insert and lock the suction head.
6
Wet vacuum cleaning
Inserting the rubber lips
Illustration
 Remove the brush strips.
 Install the rubber lips.
Note: The structured side of the rubber lips
must point outwards.
Remove the paper filter bag
If the appliance is used to vacuum wet
dirt the paper filter bag or the mem-
brane filter (special accessory) must al-
ways be removed.
It is recommended to use a special filter
bag (wet) (see Filter systems).
Drain off dirt water
Illustration
 Drain off dirty water through the drain-
age hose.
General
If wet dirt is vacuumed with the uphol-
stery or crevice nozzle or if water is
sucked up from a container it is recom-
mended to deactivate the "Filter De-
dusting" function.
If the maximum liquid level is reached
the appliance will turn off automatically.
In case of non-conductive liquids
(such as emulsion drilling fluids,
oils, and greases) the appliance is
not turned off when the container is
full. The filling level must be continu-
ously monitored and the container
must be emptied in time.
After the wet vacuuming: Clean the flat
folded filter with the filter cleaning.
Clean the electrodes with a brush.
Clean the container with a damp rag
and dry it.

Clip connection

Illustration
The suction hose is equipped with a clip
system. All C-40/C-DN-40 accessories can
be connected.
– 2
EN

Publicidad

Tabla de contenido
loading