VERTICAL EXHAUST INSTALLATION
1
No Screen or Cap
2
Wall
3
2 in. (51 mm) Minimum Clearance
4
NOTE: Where exhaust duct pierces a combustible wall or ceiling, an opening having a diameter 4 in. (102 mm)
larger than diameter of exhaust duct shall be provided, with exhaust duct centered in opening.
5
Exhaust Airflow – Maximum Length of Duct: 14 ft. (4.3 m)
M414038
4
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
CONNECT TO TUMBLER
5
HORIZONTAL EXHAUST INSTALLATION
Figure 11
Exhaust Requirements