Alliance Laundry Systems AT120FG Manual Del Usuario página 35

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1
2
CONNECT
TO TUMBLER
3
VERTICAL EXHAUST INSTALLATION
1
No Screen or Cap
2
Wall
3
2 in. (51 mm) Minimum Clearance
4
NOTE: Where exhaust duct pierces a combustible wall or ceiling, an opening having a diameter 4 in. (102 mm)
larger than diameter of exhaust duct shall be provided, with exhaust duct centered in opening.
5
Exhaust Airflow – Maximum Length of Duct: 14 ft. (4.3 m)
M414038
4
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
CONNECT TO TUMBLER
5
HORIZONTAL EXHAUST INSTALLATION
Figure 11
Exhaust Requirements
EXHAUST
OUTLET
4
T414I
2
3
1
T414I
33

Publicidad

Tabla de contenido
loading

Tabla de contenido